HP Insight Management for Tivoli User Manual
Page 43
Appendix B: HP SNMP events 43
Trap types
Rules file
Description
Netcool
severity
CpqSsBoxFltTolPwrSupplyStatus:
ok
CpqSsBoxFltTolPwrSu
pplyStatus.2
—
Clear (0)
CpqSsBoxFltTolPwrSupplyStatus:
degraded
CpqSsBoxFltTolPwrSu
pplyStatus.3
—
Major (4)
CpqSsBoxFltTolPwrSupplyStatus:f
ailed
CpqSsBoxFltTolPwrSu
pplyStatus.4
—
Critical (5)
CpqSsBoxFltTolPwrSupplyStatus:
noFltTolPower
CpqSsBoxFltTolPwrSu
pplyStatus.5
—
Minor (3)
cpqSs6FanStatusChange (8029) —
This event occurs when the fan
status of a storage system
changes.
—
CpqSsBoxFanStatus:ok
CpqSsBoxFanStatus.
2
—
Clear (0)
CpqSsBoxFanStatus:failed
CpqSsBoxFanStatus.
3
—
Major (4)
CpqSsBoxFanStatus:noFan
CpqSsBoxFanStatus.
4
—
Minor (3)
CpqSsBoxFanStatus:degraded
CpqSsBoxFanStatus.
5
—
Major (4)
cpqSs6TempStatusChange
(8030)
—
This event occurs when the
temperature status of a storage
system changes.
—
cpqSsBoxTempStatus:ok
cpqSsBoxTempStatus
.2
—
Clear (0)
cpqSsBoxTempStatus:degraded cpqSsBoxTempStatus
.3
—
Major (4)
cpqSsBoxTempStatus:failed
cpqSsBoxTempStatus
.4
—
Critical (5)
cpqSsBoxTempStatus:noTemp
cpqSsBoxTempStatus
.5
—
Minor (3)
cpqSs6PwrSupplyStatusChange
(8031)
—
This event occurs when the power
supply status of a storage system
changes.
—
CpqSsBoxFltTolPwrSupplyStatus:
ok
CpqSsBoxFltTolPwrSu
pplyStatus.2
—
Clear (0)
CpqSsBoxFltTolPwrSupplyStatus:
degraded
CpqSsBoxFltTolPwrSu
pplyStatus.3
—
Major (4)
CpqSsBoxFltTolPwrSupplyStatus:f
ailed
CpqSsBoxFltTolPwrSu
pplyStatus.4
—
Critical (5)
CpqSsBoxFltTolPwrSupplyStatus:
noFltTolPower
CpqSsBoxFltTolPwrSu
pplyStatus.5
—
Minor (3)
cpqSsConnectionStatusChange(8
032)
—
This event occurs when the status
of the Storage system connection
changes
—
cpqSsBoxConnectionStatus:
notSupported
cpqSsBoxConnection
Status.2
—
Clear (0)