HP Insight Management for Tivoli User Manual
Page 36
![background image](/manuals/398556/36/background.png)
Appendix B: HP SNMP events 36
Trap types
Rules file
Description
Netcool
severity
cpqHe3FltTolPowerSupplyInserte
d (6033)
6033
This event occurs when a fault
tolerant power supply has been
inserted into the specified chassis
and bay location.
Clear (0)
cpqHe3FltTolPowerSupplyRemov
ed (6034)
6034
This event occurs when a fault
tolerant power supply is removed
from the specified chassis and bay
location.
Minor (3)
cpqHe3FltTolFanDegraded
(6035)
6035
This event occurs when the fault
tolerant fan condition is set to
Degraded for the specified
chassis and fan.
Major (4)
cpqHe3FltTolFanFailed (6036)
6036
This event occurs when the fault
tolerant fan condition is set to
Failed for the specified chassis
and fan.
Major (4)
cpqHe3FltTolFanRedundancyLost
(6037)
6037
This event occurs when the fault
tolerant fans have lost redundancy
for the specified chassis.
Major (4)
cpqHe3FltTolFanInserted (6038) 6038
This event occurs when a fault
tolerant fan is inserted into the
specified chassis and fan location.
Clear (0)
cpqHe3FltTolFanRemoved
(6039)
6039
This event occurs when a fault
tolerant fan is removed from the
specified chassis and fan location.
Major (4)
cpqHe3TemperatureFailed
(6040)
6040
This event occurs when the
temperature status is set to
Failed in the specified chassis
and location.
Critical (5)
cpqHe3TemperatureDegraded
(6041)
—
This event occurs when the
temperature status is set to
Degraded in the specified chassis
and location.
—
cpqHeThermalDegradedAction:c
ontinue
cpqHeThermalDegra
dedAction.2
—
Major (4)
cpqHeThermalDegradedAction:s
hutdown
cpqHeThermalDegra
dedAction.3
—
Major (4)
cpqHe3TemperatureOk (6042) 6042
This event occurs when the
temperature status is set to OK in
the specified chassis and location.
Clear (0)
cpqHe3PowerConverterDegrade
d (6043)
6043
This event occurs when the DC-DC
power converter condition is set to
Degraded for the specified
chassis, slot and socket.
Major (4)
cpqHe3PowerConverterFailed
(6044)
6044
This event occurs when the DC-DC
power converter condition is set to
Failed for the specified chassis,
slot and socket.
Critical (5)