Console management controller (cpqcmc.mib) – HP Insight Management for Tivoli User Manual
Page 65
Appendix B: HP SNMP events 65
Trap types
Rules file
Description
Netcool
severity
cpqRackServerBladePoweredOff(
22070)
22070
This event occurs when the
server blade is powered off.
Clear (0)
cpqRackInformationalEAETrap(22
071)
22071
This event occurs for EAE
Informational trap.
Clear(0)
cpqRackMinorEAETrap(22072)
22072
This event occurs for EAE Minor
trap.
Major(4)
cpqRackMajorEAETrap(22073)
22073
This event occurs for EAE Major
trap.
Critical(5)
cpqRackCriticalEAETrap(22074) 22074
This event occurs for EAE
Critical trap.
Critical(5)
cpqRackPowerMinorEAETrap(220
75)
22075
This event occurs when
FlexFabric Cmdr Power
Subsystem Minor trap occurs.
Minor(3)
cpqRackPowerMajorEAETrap(22
076)
22076
This event occurs when
FlexFabric Cmdr Power
Subsystem Major trap occurs.
Major(4)
cpqRackPowerCriticalEAETrap(22
077)
22077
This event occurs when
FlexFabric Cmdr Power
Subsystem Critical trap occurs.
Critical(5)
Console management controller (CPQCMC.MIB)
Trap types
Rules file
Description
Netcool
severity
cpqCmcalarmTemp1 (153001)
—
This event occurs when the
temperature at rack sensor 1 is
outside the specified threshold.
—
CpqCmcStatusTemp1: normal
CpqCmcStatusTemp1
.2
—
Clear (0)
CpqCmcStatusTemp1:Minor (3)
CpqCmcStatusTemp1
.3
—
Minor (3)
CpqCmcStatusTemp1:overMax
CpqCmcStatusTemp1
.4
—
Major (4)
CpqCmcStatusTemp1:underMin
CpqCmcStatusTemp1
.5
—
Major (4)
CpqCmcStatusTemp1:noSensor
CpqCmcStatusTemp1
.6
—
Major (4)
CpqCmcStatusTemp1:error
CpqCmcStatusTemp1
.7
—
Critical (5)
cpqCmcalarmTemp2 (153002)
—
This event occurs when the
temperature at rack sensor 2 is
outside the specified threshold.
—
CpqCmcStatusTemp2:normal
CpqCmcStatusTemp2
.2
—
Clear (0)
CpqCmcStatusTemp2:Minor (3)
CpqCmcStatusTemp2
.3
—
Minor (3)