HP Insight Management for Tivoli User Manual
Page 61
Appendix B: HP SNMP events 61
Trap types
Rules file
Description
Netcool
severity
cpqRackPowerSupplyFailed
(22013)
22013
This event occurs when the
power supply status is set to
Failed.
Critical (5)
cpqRackPowerSupplyDegraded
(22014)
22014
This event occurs when the
power supply status is set to
Degraded.
Major (4)
cpqRackPowerSupplyOk (22015) 22015
This event occurs when the
power supply status is set to OK.
Clear (0)
cpqRackPowerSupplyRemoved
(22016)
22016
This event occurs when the
power supply is removed.
Minor (3)
cpqRackPowerSupplyInserted
(22017)
22017
This event occurs when the
power supply is inserted.
Clear (0)
cpqRackPowerSubsystemNotRedu
ndant (22018)
22018
This event occurs when the rack
power subsystem is no longer in
a redundant state.
Major (4)
cpqRackPowerSubsystemLineVolta
geProblem (22019)
—
This event occurs when the rack
power supply detected an input
line voltage problem.
—
CpqRackPowerSupplyInputLineSta
tus:noError
CpqRackPowerSuppl
yInputLineStatus.1
—
Clear (0)
CpqRackPowerSupplyInputLineSta
tus:lineOverVoltage
CpqRackPowerSuppl
yInputLineStatus.2
—
Major (4)
CpqRackPowerSupplyInputLineSta
tus:lineUnderVoltage
CpqRackPowerSuppl
yInputLineStatus.3
—
Major (4)
CpqRackPowerSupplyInputLineSta
tus:lineHit
CpqRackPowerSuppl
yInputLineStatus.4
—
Major (4)
CpqRackPowerSupplyInputLineSta
tus:brownout
CpqRackPowerSuppl
yInputLineStatus.5
—
Major (4)
CpqRackPowerSupplyInputLineSta
tus:linePowerLoss
CpqRackPowerSuppl
yInputLineStatus.6
—
Critical (5)
cpqRackPowerSubsystemOverloa
dCondition (22020)
22020
This event occurs when there is
a rack power subsystem
overload condition.
Major (4)
cpqRackPowerShedAutoShutdow
n (22021)
22021
This event occurs when the
server blade shuts down due to
lack of power.
Critical (5)
cpqRackServerPowerOnFailedNot
Redundant (22022)
22022
This event occurs when there is
not enough power to power on
the server blade and maintain
redundancy for the other blades
in the enclosure.
Major (4)
cpqRackServerPowerOnFailedNot
EnoughPower (22023)
22023
This event occurs when there is
not enough power to power on
the server blade.
Critical (5)