beautypg.com

Switch traps (cimtraps.mib) – HP Insight Management for Tivoli User Manual

Page 71

background image

Appendix B: HP SNMP events 71


Trap types

Rules file

Description

Netcool

severity

CpqCmcStatusLock2Dev:noConne
ct

CpqCmcStatusLock2
Dev.7

Minor (3)

CpqCmcStatusLock2Dev:notAvail CpqCmcStatusLock2

Dev.8

Minor (3)

cpqCmcSetupChanged (153100) 153100

This event occurs when the setup

of console management
controller changes.

Clear (0)

Switch Traps (CIMTRAPS.MIB)

Trap types

Rules file

Description

Netcool

severity

switchFirmwareTransferred(1610

01)

161001

This event occurs when the

firmware image successfully
transferred.

Clear (0)

switchConfigFileTransferred
(161002)

161002

This event occurs when the
configuration file successfully

transferred.

Clear (0)

switchTFTPTransferSucceeded

(161003)

161003

This event occurs when the TFTP

transfer completed successfully.

Clear (0)

switchTFTPTransferFailed

(161004)

161004

This event occurs when the switch

fails a TFTP transfer.

Minor (3)

switchFileInvalid (161005)

161005

This event occurs when an invalid

firmware or configuration image
is downloaded.

Minor (3)

switchFanFailed (161006)

161006

This event occurs when the

condition of switch fan fails.

Critical (5)

switchFanOk (161007)

161007

This event occurs when the switch

fan returns to normal operation.

Clear (0)

switchTempSensorDegraded

(161008)

161008

This event occurs when the switch

temperature sensor indicates high
temperature.

Major (4)

switchTempSensorFailed
(161009)

161009

This event occurs when the switch
temperature sensor indicates an

over temperature.

Critical (5)

switchTempSensorOk (161010)

161010

This event occurs when the switch

temperature sensor indicates
normal temperature.

Clear (0)

switchPostSuccess (161011)

161011

This event occurs when the switch

successfully completes POST.

Minor (3)

switchLoginFailure (161012)

161012

This event occurs when the switch
rejects a login attempt.

Minor (3)

switchLocationChange (161013) 161013

This event occurs when the switch
location changes; trap is sent on

the next boot.

Clear (0)