Server health features (cpqhlth.mib) – HP Insight Management for Tivoli User Manual
Page 34
Appendix B: HP SNMP events 34
Trap types
Rules file
Description
Netcool
severity
cpqSasLogDrvStatusChange
(5023)
—
This event occurs when the status
of a SAS or SATA logical drive
changes.
—
CpqSasLogDrvStatus:ok
CpqSasLogDrvStatus.
2
—
Clear (0)
CpqSasLogDrvStatus:degraded CpqSasLogDrvStatus.
3
—
Minor (3)
CpqSasLogDrvStatus:rebuilding CpqSasLogDrvStatus.
4
—
Minor (3)
CpqSasLogDrvStatus:failed
CpqSasLogDrvStatus.
5
—
Critical (5)
CpqSasLogDrvStatus:offline
CpqSasLogDrvStatus.
6
—
Critical (5)
CpqSas2TapeDrvStatusChange
(5025)
—
This event occurs when the status
of a SAS tape drive changes.
—
cpqSasTapeDrvStatus: ok
cpqSasTapeDrvStatus
.2
—
Clear (0)
cpqSasTapeDrvStatus: offline
cpqSasTapeDrvStatus
.3
—
Critical (5)
Server health features (CPQHLTH.MIB)
Trap types
Rules file
Description
Netcool
severity
cpqHe3CorrectableMemoryLogD
isabled (6016)
—
This event occurs when the
frequency of correctable memory
errors is so high that the error
tracking logic has been
temporarily disabled.
—
cpqHeCorrMemLogStatus:notSup
ported
cpqHeCorrMemLogSt
atus.2
—
Minor (3)
cpqHeCorrMemLogStatus:disabl
ed
cpqHeCorrMemLogSt
atus.3
—
Major (4)
cpqHeCorrMemLogStatus:enable
d
cpqHeCorrMemLogSt
atus.4
—
Clear (0)
cpqHe3ThermalTempFailed
(6017)
6017
This event occurs when the
temperature status has been set to
fail.
Critical (5)
cpqHe3ThermalTempDegraded
(6018)
—
This event occurs when the server's
temperature is outside of the
normal operating range.
—
cpqHeThermalDegradedAction:c
ontinue
cpqHeThermalDegra
dedAction.2
—
Major (4)
cpqHeThermalDegradedAction:s
hutdown
cpqHeThermalDegra
dedAction.3
—
Major (4)