HP Insight Management for Tivoli User Manual
Page 80
Appendix B: HP SNMP events 80
Trap types
Rules file
Description
Netcool
severity
36(13601590)
firmware revision is detected by the
physical disk drive firmware load process.
sCellEventTrap-06-
37(13601591)
13601591
This event occurs when a Fibre Channel
physical disk drive firmware revision is
detected by the physical disk drive
firmware load process that is later than
the latest known supported revision.
Clear (0)
sCellEventTrap-06-
38(13601592)
13601592
This event occurs when a Fibre Channel
physical disk drive firmware revision is
detected by the physical disk drive
firmware load process that has a newer
supported revision available.
Clear (0)
sCellEventTrap-06-
40(13601600)
13601600
This event occurs when a Fibre Channel
physical disk drive that has new
capabilities has been detected.The
physical disk drive has properties that
might or might not be compatible with this
release of Enterprise Virtual Array
firmware. The drive is prevented from
being used until the Approved Drive
Firmware table is updated to allow it.
Critical(5)
sCellEventTrap-06-
41(13601601)
13601601
This event occurs when the device loop
configuration has changed on a HSV300
controller Fibre Channel port. This
informational event contains a page of the
newly genereated fibre channel loop
map.Devices are listed in loop order
using their ALPAs.
Clear (0)
sCellEventTrap-06-
42(13601602)
13601602
This event occurs when a user command
sends to a physical disk drive.
Clear (0)
sCellEventTrap-06-
4b(13601611)
13601611
This event occurs when the HSV300
controller is instructed to Enable or
Disable Loop Recovery Operations
Clear (0)
sCellEventTrap-06-
4c(13601612)
13601612
This event occurs when Device Fibre
Channel physical disk drive is placed on
the Drive Suspect List (DSL)
.
Clear (0)
sCellEventTrap-06-
4d(13601613)
13601613
This event occurs when the HSV300
controller is finished attempting to
codeload all Drive Enclosure
Environmental Monitoring Unit hardware
requiring updates and completes
staggered codeload, if necessary.
Clear (0)
sCellEventTrap-06-
4e(13601614)
13601614
This event occurs when a physical disk
drive reports a non-zero RSP_CODE in
response to an I/O.
Clear (0)
sCellEventTrap-06-
4f(13601615)
13601615
This event occurs when an Enclosure Link
Module begins updating its code. Do not
power down the Enclosure until the code
update is complete.
Clear (0)
sCellEventTrap-06-
13601616
This event occurs when an Enclosure Link
Clear (0)