beautypg.com

HP Insight Management for Tivoli User Manual

Page 80

background image

Appendix B: HP SNMP events 80


Trap types

Rules file

Description

Netcool

severity

36(13601590)

firmware revision is detected by the
physical disk drive firmware load process.

sCellEventTrap-06-

37(13601591)

13601591

This event occurs when a Fibre Channel

physical disk drive firmware revision is
detected by the physical disk drive

firmware load process that is later than
the latest known supported revision.

Clear (0)

sCellEventTrap-06-

38(13601592)

13601592

This event occurs when a Fibre Channel

physical disk drive firmware revision is
detected by the physical disk drive

firmware load process that has a newer
supported revision available.

Clear (0)

sCellEventTrap-06-
40(13601600)

13601600

This event occurs when a Fibre Channel
physical disk drive that has new

capabilities has been detected.The
physical disk drive has properties that
might or might not be compatible with this

release of Enterprise Virtual Array
firmware. The drive is prevented from
being used until the Approved Drive

Firmware table is updated to allow it.

Critical(5)

sCellEventTrap-06-

41(13601601)

13601601

This event occurs when the device loop

configuration has changed on a HSV300
controller Fibre Channel port. This
informational event contains a page of the

newly genereated fibre channel loop
map.Devices are listed in loop order
using their ALPAs.

Clear (0)

sCellEventTrap-06-

42(13601602)

13601602

This event occurs when a user command

sends to a physical disk drive.

Clear (0)

sCellEventTrap-06-

4b(13601611)

13601611

This event occurs when the HSV300

controller is instructed to Enable or
Disable Loop Recovery Operations

Clear (0)

sCellEventTrap-06-

4c(13601612)

13601612

This event occurs when Device Fibre

Channel physical disk drive is placed on
the Drive Suspect List (DSL)

.

Clear (0)

sCellEventTrap-06-

4d(13601613)

13601613

This event occurs when the HSV300

controller is finished attempting to
codeload all Drive Enclosure

Environmental Monitoring Unit hardware
requiring updates and completes
staggered codeload, if necessary.

Clear (0)

sCellEventTrap-06-
4e(13601614)

13601614

This event occurs when a physical disk
drive reports a non-zero RSP_CODE in

response to an I/O.

Clear (0)

sCellEventTrap-06-

4f(13601615)

13601615

This event occurs when an Enclosure Link

Module begins updating its code. Do not
power down the Enclosure until the code
update is complete.

Clear (0)

sCellEventTrap-06-

13601616

This event occurs when an Enclosure Link

Clear (0)