Storage systems information (cpqstsys.mib) – HP Insight Management for Tivoli User Manual
Page 39
Appendix B: HP SNMP events 39
Storage systems information (CPQSTSYS.MIB)
Trap types
Rules file
Description
Netcool
severity
cpqSs3FanStatusChange (8008) —
This event occurs when the fan
status of a storage system
changes.
—
CpqSsBoxFanStatus:ok
CpqSsBoxFanStatus.
2
—
Clear (0)
CpqSsBoxFanStatus:failed
CpqSsBoxFanStatus.
3
—
Major (4)
CpqSsBoxFanStatus:noFan
CpqSsBoxFanStatus.
4
—
Minor (3)
CpqSsBoxFanStatus:degraded
CpqSsBoxFanStatus.
5
—
Major (4)
cpqSs3TempFailed (8009)
8009
This event occurs when the
temperature status is set to
Failed.
Critical (5)
cpqSs3TempDegraded (8010)
8010
This event occurs when the
temperature status is set to
Degraded.
Major (4)
cpqSs3TempOk (8011)
8011
This event occurs when the
temperature status is set to OK.
Clear (0)
cpqSs3SidePanelInPlace (8012) 8012
This event occurs when the
storage system side panel is in
place.
Clear (0)
cpqSs3SidePanelRemoved
(8013)
8013
This event occurs when the
storage system side panel is
removed.
Major (4)
cpqSs4PwrSupplyDegraded
(8015)
—
This event occurs when a storage
system power supply status is set
to Degraded.
—
CpqSsBoxFltTolPwrSupplyStatus:
ok
CpqSsBoxFltTolPwrSu
pplyStatus.2
—
Clear (0)
CpqSsBoxFltTolPwrSupplyStatus:
degraded
CpqSsBoxFltTolPwrSu
pplyStatus.3
—
Major (4)
CpqSsBoxFltTolPwrSupplyStatus:f
ailed
CpqSsBoxFltTolPwrSu
pplyStatus.4
—
Critical (5)
CpqSsBoxFltTolPwrSupplyStatus:
noFltTolPower
CpqSsBoxFltTolPwrSu
pplyStatus.5
—
Minor (3)
cpqSsExPowerSupplyUpsStatusC
hange (8018)
—
This event occurs when the status
of an uninterruptible power
supply (UPS) attached to a
storage system power supply
changes.
—
CpqSsPowerSupplyUpsStatus:no
Ups
CpqSsPowerSupplyU
psStatus.2
—
Minor (3)
CpqSsPowerSupplyUpsStatus:ok CpqSsPowerSupplyU
psStatus.3
—
Clear (0)