beautypg.com

HP Insight Management for Tivoli User Manual

Page 89

background image

Appendix B: HP SNMP events 89


Trap types

Rules file

Description

Netcool

severity

changes.

sCellEventTrap-09-

77(13602423)

13602423

This event occurs when a Data

Replication Group failover occurs.

Clear (0)

sCellEventTrap-09-

78(13602424)

13602424

This event occurs when a Data

Replication Group is suspended or
resumed.

Clear (0)

sCellEventTrap-09-

79(13602425)

13602425

This event occurs when a Storage System

Virtual Disk is added to a Data

Replication Group.

Clear (0)

sCellEventTrap-09-

7a(13602426)

13602426

This event occurs when a Storage System

Virtual Disk is removed from a Data
Replication Group.

Clear (0)

sCellEventTrap-09-

7b(13602427)

13602427

This event occurs when the auto suspend

attribute of a Data Replication Group
changes.

Clear (0)

sCellEventTrap-09-
7c(13602428)

13602428

This event occurs when the destination
presentation attribute of a Data

Replication Group changes.

Clear (0)

sCellEventTrap-09-

7d(13602429

13602429

This event occurs when the flags of a

physical disk drive changes because of a
maintenance mode change.

Clear (0)

sCellEventTrap-09-
7e(13602430)

13602430

This event occurs when the defer_copy
attribute of a Data Replication Group

changes.

Clear (0)

sCellEventTrap-09-

7f(13602431)

13602431

This event occurs when a Data

Replication Group is suspended due to
link down.

Clear (0)

sCellEventTrap-09-
80(13602432)

13602432

This event occurs when a Data
Replication Group is suspended due to

site failover.

Clear (0)

sCellEventTrap-09-

81(13602433)

13602433

This event occurs when a Data

Replication Group is suspended due to
defer copy.

Clear (0)

sCellEventTrap-09-

82(13602434)

13602434

This event occurs when the split brain

allow attribute of a Data Replication

Group changes.

Clear (0)

sCellEventTrap-09-

c8(13602504)

13602504

This event occurs when an internal logical

disk transitions to the DATA LOST state.

Critical(5)

sCellEventTrap-09-

c9(13602505)

13602505

This event occurs when a Disk Group

transitions to an INOPERATIVE state.

Critical(5)

sCellEventTrap-09-

ca(13602506)

13602506

This event occurs when an internal logical

disk transitions to the FAILED state.

Critical(5)

sCellEventTrap-09-

cb(13602507)

13602507

This event occurs when an internal logical

disk transitions to the SNAPSHOT
OVERCOMMIT state.

Critical(5)

sCellEventTrap-09-
cc(13602508)

13602508

This event occurs when an internal logical
disk transitions to the DEVICE DATA LOST

state.

Critical(5)