Appendix B: HP SNMP events 22
Trap types
Rules file
Description
Netcool
severity
cpqCrExpCabTemperatureCrit
icalTrap (27)
27
This event occurs when the
temperature in the expansion
cabinet has triggered a Critical
condition detected by the controller.
Major (4)
cpqCrExpCabTemperatureInfo
rmationTrap (28)
28
This event occurs when the
temperature in the expansion
cabinet has returned to normal.
Clear (0)
cpqCrExpCabPowerSupplyInf
ormationTrap (29)
29
This event occurs when the power
supply in the expansion cabinet has
recovered.
Clear (0)
cpqCrPhyDiskInformationTrap
(30)
30
This event occurs when a disk drive
has recovered.
Clear (0)
cpqCrPhyDiskFailureTrap (31) 31
This event occurs when a disk drive
has failed.
Critical (5)
cpqCrPhyDiskReconstructTrap
(32)
32
This event occurs when a disk
member of a logical drive has
begun the reconstruction process
and will be available for use when
reconstruction is complete.
Minor (3)
cpqCrPhyDiskAvailableTrap
(33)
33
This event occurs when a disk drive
has been physically added or set to
the Available state.
Clear (0)
cpqCrPhyDiskSpareTrap (34) 34
This event occurs when a disk drive
has been set to Spare status from
Available and can be used in a
RAID 1, RAID 0+1 or RAID 5 logical
disk should a member device fail in
one of those RAIDsets.
Clear (0)
Common cluster management (SVRCLU.MIB)
Trap types
Rules file
Description
Netcool
severity
svrCluMemberAdded (100) 100
This event occurs when a cluster
member is added.
Clear (0)
svrCluMemberDeleted (101) 101
This event occurs when a cluster
member is deleted.
Minor (3)
Standard equipment (CPQSTDEQ.MIB)
Trap types
Rules file
Description
Netcool
severity
cpqSeCpuThresholdPassed
(1001)
1001
This event occurs when an internal
CPU error threshold has been
passed on a particular CPU,
causing it to go degraded.