Appendix b: hp snmp events, Hp snmp events, Cr3500 raid controller (cpqcr.mib) – HP Insight Management for Tivoli User Manual
Page 20

Appendix B: HP SNMP events 20
Appendix B: HP SNMP events
HP SNMP events
The following tables list all of the HP ProLiant SNMP definitions delivered with the rules file for
Netcool/OMNIbus v5.0. The events are organized according to MIB type and object identifier.
CR3500 RAID controller (CPQCR.MIB)
Trap types
Rules file
Description
Netcool
severity
cpqCrController1FailureTrap
(1)
1
This event occurs when the primary
controller in the subsystem has
failed.
Critical (5)
cpqCrController1InformationTr
ap (2)
2
This event occurs when the primary
controller in the subsystem has
recovered.
Clear (0)
cpqCrController2FailureTrap
(3)
3
This event occurs when the
secondary controller in the
subsystem has failed.
Critical (5)
cpqCrController2InformationTr
ap (4)
4
This event occurs when the
secondary controller in the
subsystem has recovered.
Clear (0)
cpqCrLogDriveInformationTrap
(5)
5
This event occurs when a RAIDset
has become optimal.
Clear (0)
cpqCrLogDriveFailureTrap (6) 6
This event occurs when a RAIDset
has failed.
Critical (5)
cpqCrLogDriveReconstructTrap
(7)
7
This event occurs when a RAIDset
has started the reconstruction
process.
Minor (3)
cpqCrLogDriveReducedTrap
(8)
8
This event occurs when a RAIDset
has become degraded.
Major (4)
cpqCrLogDriveInitializingTrap
(9)
9
This event occurs when a RAIDset is
initializing.
Minor (3)
cpqCrDiskInformationTrap
(10)
10
This event occurs when a disk drive
has recovered.
Clear (0)
cpqCrDiskFailureTrap (11)
11
This event occurs when a disk drive
fails.
Critical (5)
cpqCrDiskReconstructTrap
(12)
12
This event occurs when a disk
member of a logical drive has
begun the reconstruction process
and will be available for use when
reconstruction is complete.
Minor (3)