Appendix B: HP SNMP events 44


Trap types

Rules file

Description

Netcool

severity

cpqSsBoxConnectionStatus:
connected

cpqSsBoxConnection
Status.3

Clear (0)

cpqSsBoxConnectionStatus:
notConnected

cpqSsBoxConnection
Status.4

Critical (5)

Remote Insight board information (CPQSM2.MIB)

Trap types

Rules file

Description

Netcool
severity

cpqSm2ServerReset (9001)

9001

This event occurs when the Remote

Insight/ Integrated Lights-Out firmware
detects a server reset.

Minor (3)

cpqSm2ServerPowerOutage

(9002)

9002

This event occurs when the Remote

Insight/ Integrated Lights-Out firmware
detects a server power failure.

Critical (5)

cpqSm2UnauthorizedLoginAttem

pts (9003)

9003

This event occurs when the Remote

Insight/ Integrated Lights-Out firmware
detects unauthorized login attempts.

Minor (3)

cpqSm2BatteryFailed (9004)

9004

This event occurs when the Remote Insight

battery fails and must be replaced.

Major (4)

cpqSm2SelfTestError (9005)

9005

This event occurs when the Remote

Insight/ Integrated Lights-Out firmware
detects a Remote Insight self test error.

Major (4)

cpqSm2InterfaceError (9006)

9006

This event occurs when the host operating

system detects an error in the Remote
Insight/ Integrated Lights-Out interface
and the firmware is not responding.

Major (4)

cpqSm2BatteryDisconnected
(9007)

9007

This event occurs when the Remote Insight
battery cable is disconnected.

Major (4)

cpqSm2KeyboardCableDisconne
cted (9008)

9008

This event occurs when the Remote Insight
keyboard cable is disconnected.

Major (4)

cpqSm2MouseCableDisconnecte

d (9009)

9009

This event occurs when the Remote Insight

mouse cable is disconnected.

Major (4)

cpqSm2ExternalPowerCableDisc

onnected (9010)

9010

This event occurs when the Remote Insight

external power cable is disconnected.

Major (4)

cpqSm2LogsFull (9011)

9011

This event occurs when the Remote

Insight/ Integrated Lights-Out firmware
detects the logs are full.

Minor (3)

cpqSm2SecurityOverrideEngage

d (9012)

9012

This event occurs when the Remote

Insight/Integrated Lights-Out firmware
detects the security override jumper has

been toggled to the engaged position.

Minor (3)

cpqSm2SecurityOverrideDisenga

ged (9013)

9013

This event occurs when the Remote

Insight/Integrated Lights-Out firmware
detects the security override jumper is

toggled to the disengaged position.

Minor (3)