cpqSsBoxConnectionStatus:
connected
cpqSsBoxConnection
Status.3
—
Clear (0)
cpqSsBoxConnectionStatus:
notConnected
cpqSsBoxConnection
Status.4
—
Critical (5)
Remote Insight board information (CPQSM2.MIB)
Trap types
Rules file
Description
Netcool
severity
cpqSm2ServerReset (9001)
9001
This event occurs when the Remote
Insight/ Integrated Lights-Out firmware
detects a server reset.
Minor (3)
cpqSm2ServerPowerOutage
(9002)
9002
This event occurs when the Remote
Insight/ Integrated Lights-Out firmware
detects a server power failure.
Critical (5)
cpqSm2UnauthorizedLoginAttem
pts (9003)
9003
This event occurs when the Remote
Insight/ Integrated Lights-Out firmware
detects unauthorized login attempts.
Minor (3)
cpqSm2BatteryFailed (9004)
9004
This event occurs when the Remote Insight
battery fails and must be replaced.
Major (4)
cpqSm2SelfTestError (9005)
9005
This event occurs when the Remote
Insight/ Integrated Lights-Out firmware
detects a Remote Insight self test error.
Major (4)
cpqSm2InterfaceError (9006)
9006
This event occurs when the host operating
system detects an error in the Remote
Insight/ Integrated Lights-Out interface
and the firmware is not responding.
Major (4)
cpqSm2BatteryDisconnected
(9007)
9007
This event occurs when the Remote Insight
battery cable is disconnected.
Major (4)
cpqSm2KeyboardCableDisconne
cted (9008)
9008
This event occurs when the Remote Insight
keyboard cable is disconnected.
Major (4)
cpqSm2MouseCableDisconnecte
d (9009)
9009
This event occurs when the Remote Insight
mouse cable is disconnected.
Major (4)
cpqSm2ExternalPowerCableDisc
onnected (9010)
9010
This event occurs when the Remote Insight
external power cable is disconnected.
Major (4)
cpqSm2LogsFull (9011)
9011
This event occurs when the Remote
Insight/ Integrated Lights-Out firmware
detects the logs are full.
Minor (3)
cpqSm2SecurityOverrideEngage
d (9012)
9012
This event occurs when the Remote
Insight/Integrated Lights-Out firmware
detects the security override jumper has
been toggled to the engaged position.
Minor (3)
cpqSm2SecurityOverrideDisenga
ged (9013)
9013
This event occurs when the Remote
Insight/Integrated Lights-Out firmware
detects the security override jumper is
toggled to the disengaged position.
Minor (3)