HP Insight Management for Tivoli User Manual
Page 86
![background image](/manuals/398556/86/background.png)
Appendix B: HP SNMP events 86
Trap types
Rules file
Description
Netcool
severity
removed from the power supply.
sCellEventTrap-09-
29(13602345)
13602345
This event occurs when an HSV300
controller 2 blower or power supply
assembly is reinstalled or AC power is
restored to the power supply.
Clear (0)
sCellEventTrap-09-
2a(13602346)
13602346
This event occurs when an HSV300
controller 1 blower or power supply is
running slower than the lowest acceptable
speed.
Critical(5)
sCellEventTrap-09-
2b(13602347)
13602347
This event occurs when an HSV300
controller 2 blower or power supply is
running slower than the lowest acceptable
speed.
Critical(5)
sCellEventTrap-09-
2c(13602348)
13602348
This event occurs when an HSV300
controller battery assembly transitions to
the Battery System Hold-up Time
is zero hour state.
Minor(3)
sCellEventTrap-09-
2d(13602349)
13602349
This event occurs when the resource
availability state of a volume transitions to
the INSUFFICIENT state.
Critical(5)
sCellEventTrap-09-
2e(13602350)
13602350
This event occurs when an HSV300
controller rejects a login attempt.
Clear (0)
sCellEventTrap-09-
2f(13602351)
13602351
This event occurs when an HSV300
controller processes a Storage System
Management Interface command with the
result of an unsuccessful return code.
Clear (0)
sCellEventTrap-09-
30(13602352)
13602352
This event occurs when an HSV300
controller updates the physical disk drive
map for a loop pair.
Clear (0)
sCellEventTrap-09-
31(13602353)
13602353
This event occurs when a physical disk
drive transitionsd to DEGRADED state.
Critical(5)
sCellEventTrap-09-
32(13602354)
13602354
This event occurs when a physical disk
drive transitionsd to FAILED state.
Critical(5)
sCellEventTrap-09-
33(13602355)
13602355
This event occurs when a Derived Unit is
created.
Clear (0)
sCellEventTrap-09-
34(13602356)
13602356
This event occurs when a logical disk is
created.
Clear (0)
sCellEventTrap-09-
35(13602357)
13602357
This event occurs when a Disk Group is
created.
Clear (0)
sCellEventTrap-09-
36(13602358)
13602358
This event occurs when a physical disk
drive is discovered.
Clear (0)
sCellEventTrap-09-
37(13602359)
13602359
This event occurs when a Presented Unit is
created.
Clear (0)
sCellEventTrap-09-
38(13602360)
13602360
This event occurs when a Storage System
Host Path is created.
Clear (0)
sCellEventTrap-09-
39(13602361)
13602361
This event occurs when a Storage System
Virtual Disk is created.
Clear (0)