Appendix B: HP SNMP events 171
Trap types
Rules file
Description
Netcool
severity
vcModPortOutputUtilizationUp(1
3)
13
This event occurs when the port output
utilization rate exceeds high threshold.
Minor(3)
vcModPortOutputUtilizationDow
n(14)
14
This event occurs when the port output
utilization rate drops below low
watermark.
Minor(3)
vcModPortInputErrorsUp(15)
15
This event occurs when the input error
count on a port exceeds high watermark.
Minor(3)
vcModPortInputErrorsDown(16) 16
This event occurs when the input error
count on a port drops below low
watermark.
Minor(3)
vcModPortOutputErrorsUp(17)
17
This event occurs when the output error
count on a port exceeds its high
watermark.
Minor(3)
vcModPortOutputErrorsDown(18
)
18
This event occurs when the output error
count on a port drops below its low
watermark.
Minor(3)
HP Storage cpqHSV Management MIB (evapamib-mib)
Trap types
Rules file
Description
Netcool
severity
hpevapaAlarmsTrap (4)
4
This event occurs for EVA Performance
Advisor Alarms Trap.
Warning(2)
LeftHand Networks notifications-MIB (LEFTHAND-NETWORKS-
NSM-NOTIFICATION-MIB)
Trap types
Rules file
Description
Netcool
severity
lhnNsmNotificationGeneric (1)
—
This event occurs when a generic system
event is generated.
—
Severity: critical
severity.0
Critical(5)
Severity: warning
severity.1
Warning(2)
Severity: info
severity.2
Clear(0)
lhnNsmNotificationBackplane(2) —
This event occurs when an event for the
system backplane is generated.
—
Severity: critical
severity.0
Critical(5)
Severity: warning
severity.1
Warning(2)
Severity: info
severity.2
Clear(0)
lhnNsmNotificationController(3) —
This event occurs when an event for the
RAID controller is generated.
—
Severity: critical
severity.0
Critical(5)
Severity: warning
severity.1
Warning(2)