Operating system management (cpqwinos.mib) – HP Insight Management for Tivoli User Manual
Page 53
Appendix B: HP SNMP events 53
Trap types
Rules file
Description
Netcool
severity
cpqNic3ConnectivityRestored
(18011)
18011
This event occurs when the physical
adapter in a single adapter
configuration returns to the OK
condition or at least one physical
adapter in a logical adapter group
returns to the OK condition.
Clear (0)
cpqNic3ConnectivityLost (18012) 18012
This event occurs when the adapter in
a single adapter configuration fails or
when the last adapter in a redundant
configuration fails.
Critical (5)
cpqNic3RedundancyIncreased
(18013)
18013
This event occurs when a previously
failed physical adapter in a connected
logical adapter group returns to the
OK condition.
Clear (0)
cpqNic3RedundancyReduced
(18014)
18014
This event occurs when a physical
adapter in a logical adapter group
changes to the Failed condition but
at least one physical adapter remains
in the OK condition.
Major (4)
Operating system management (CPQWINOS.MIB)
Trap types
Rules file Description
Netcool
severity
cpqOsCpuTimeDegraded
(19001)
19001
This event occurs when the Processor Time
performance property is set to Degraded.
Major (4)
cpqOsCpuTimeFailed (19002)
19002
This event occurs when the Processor Time
performance property is set to Critical.
Major (4)
cpqOsCacheCopyReadHitsDegra
ded (19003)
19003
This event occurs when the Cache
CopyReadHits performance property is set
to Degraded.
Major (4)
cpqOsCacheCopyReadHitsFailed
(19004)
19004
This event occurs when the Cache
CopyReadHits performance property is set
to Critical.
Major (4)
cpqOsPageFileUsageDegraded
(19005)
19005
This event occurs when the PagingFile
Usage performance property is set to
Degraded.
Major (4)
cpqOsPageFileUsageFailed
(19006)
19006
This event occurs when the PagingFile
Usage performance property is set to
Critical.
Major (4)
cpqOsLogicalDiskBusyTimeDegra
ded (19007)
19007
This event occurs when the LogicalDisk
BusyTime performance property is set to
Degraded.
Major (4)
cpqOsLogicalDiskBusyTimeFailed
(19008)
19008
This event occurs when the LogicalDisk
BusyTime performance property is set to
Critical.
Major (4)