HP Insight Management for Tivoli User Manual
Page 104
![background image](/manuals/398556/104/background.png)
Appendix B: HP SNMP events 104
Trap types
Rules file
Description
Netcool
severity
3a(13603642)
module is operating normally.
sCellEventTrap-0e-
3b(13603643)
13603643
This event occurs when the Management
module malfunctions.
Critical(5)
sCellEventTrap-0e-
3c(13603644)
13603644
This event occurs when the Battery
module operation is degraded.
Minor(3)
sCellEventTrap-0e-
3d(13603645)
13603645
This event occurs when the Fan module
configuration is incorrect.
Critical(5)
sCellEventTrap-0e-
3e(13603646)
13603646
This event occurs when the Fan module
operation is degraded.
Minor(3)
sCellEventTrap-0e-
3f(13603647)
13603647
This event occurs when the Fan module is
operating normally.
Clear (0)
sCellEventTrap-0e-
40(13603648)
13603648
This event occurs when the power supply
is operating normally.
Clear (0)
sCellEventTrap-0e-
41(13603649)
13603649
This event occurs when the temperature
within an HSV300 controller returns to a
safe operating level.
Minor(3)
sCellEventTrap-0e-
42(13603650)
13603650
This event occurs when the temperature
within an HSV300 controller is becoming
too cold.
Minor(3)
sCellEventTrap-0e-
43(13603651)
13603651
This event occurs when the temperature
within an HSV300 controller is too cold.
Critical(5)
sCellEventTrap-0e-
44(13603652)
13603652
This event occurs when the temperature
within an HSV300 controller is updated.
Clear (0)
sCellEventTrap-0e-
45(13603653)
13603653
This event occurs when the temperature
sensor within an HSV300 controller
malfunctions.
Minor(3)
sCellEventTrap-0e-
46(13603654)
13603654
This event occurs when the Management
module operation is degraded.
Minor(3)
sCellEventTrap-0e-
47(13603655)
13603655
This event occurs when the Management
module status changes.
Clear (0)
sCellEventTrap-0e-
48(13603656)
13603656
This event occurs when the Initial status of
network switch embedded in an HSV300
controller.
Clear (0)
sCellEventTrap-0e-
49(13603657)
13603657
This event occurs when the normal
operation of network switch embedded in
an HSV300 controller.
Clear (0)
sCellEventTrap-0e-
4a(13603658)
13603658
This event occurs when the malfunction of
network switch embedded in an HSV300
controller.
Critical(5)
sCellEventTrap-0e-
4b(13603659)
13603659
This event occurs when the degraded
operation of the network switch
embedded in an HSV300 controller.
Minor(3)
sCellEventTrap-0e-
4c(13603660)
13603660
This event occurs when the status change
of the network switch embedded in
HSV300 controller.
Clear (0)
sCellEventTrap-0e-
4d(13603661)
13603661
This event occurs when the status change
of I/O module embedded in an HSV300
Clear (0)