Appendix B: HP SNMP events 37
Trap types
Rules file
Description
Netcool
severity
cpqHe3PowerConverterRedunda
ncyLost (6045)
6045
This event occurs when the DC-DC
power converters have lost
redundancy for the specified
chassis.
Major (4)
cpqHe3CacheAccelParityError
(6046)
6046
This event occurs when a cache
accelerator parity error indicates a
cache module must be replaced.
Major (4)
cpqHeResilientMemOnlineSpare
Engaged (6047)
6047
This event occurs when the
Advanced Memory Protection
subsystem detects a memory fault
and online spare memory has
been activated.
Major (4)
cpqHe4FltTolPowerSupplyOk
(6048)
6048
This event occurs when the fault
tolerant power supply condition
returns to the OK state for the
specified chassis and bay location.
Clear (0)
cpqHe4FltTolPowerSupplyDegra
ded (6049)
6049
This event occurs when the fault
tolerant power supply condition is
set to Degraded for the specified
chassis and bay location.
Major (4)
cpqHe4FltTolPowerSupplyFailed
(6050)
6050
This event occurs when the fault
tolerant power supply condition is
set to Failed for the specified
chassis and bay location.
Major (4)
cpqHeResilientMemMirroredMe
moryEngaged (6051)
6051
This event occurs when the
Advanced Memory Protection
subsystem detects a memory fault
and Mirrored memory is activated.
Major (4)
cpqHeResilientAdvancedECCMe
moryEngaged (6052)
6052
This event occurs when the
Advanced Memory Protection
subsystem detects a memory fault
and Advanced ECC is activated.
Major (4)
cpqHeResilientMemXorMemoryE
ngaged (6053)
6053
This event occurs when the
Advanced Memory Protection
subsystem detects a memory fault
and XOR engine memory is
activated.
Major (4)
cpqHe3FltTolPowerRedundancyR
estored (6054)
6054
This event occurs when the fault
tolerant power supplies return to a
redundant state for the specified
chassis.
Clear (0)
cpqHe3FltTolFanRedundancyRest
ored (6055)
6055
This event occurs when the fault
tolerant fans return to a redundant
state for the specified chassis.
Clear (0)
cpqHe4CorrMemReplaceMemM
odule (6056)
6056
This event occurs when the
correctable memory errors are
corrected, but the memory module
should be replaced.
Major (4)