Lsi logic scsi storage adapters (symtrap.mib), Virtual connect module mib (vc-module-mib) – HP Insight Management for Tivoli User Manual
Page 170
Appendix B: HP SNMP events 170
Trap types
Rules file
Description
Netcool
severity
hpHttpMgDeviceRemovedTrap
(9)
9
This event occurs when is removed from
the MIB.
Minor (3)
LSI Logic SCSI Storage Adapters (SYMTRAP.MIB)
Trap types
Rules file
Description
Netcool
severity
symSCSI1 (101)
101
This event occurs when the Symbios SCSI
agent is up.
Clear (0)
symSCSI2 (102)
102
This event occurs when the Symbios SCSI
agent is down.
Clear (0)
symSCSI3 (108)
108
This event occurs when a new SCSI
controller is discovered.
Clear (0)
symSCSI4 (109)
109
This event occurs when a SCSI controller
is replaced by another adapter of
different family type.
Major (4)
symSCSI5 (110)
110
This event occurs when a SCSI controller
fails.
Critical (5)
symSCSI6 (111)
111
This event occurs when a previously failed
SCSI adapter s recovers.
Clear (0)
symSCSI7 (112)
112
This event occurs when an attached SCSI
device fails.
Critical (5)
symSCSI8 (113)
113
This event occurs when a previously
unknown device is found.
Clear (0)
symSCSI9 (114)
114
This event occurs when a previously failed
device starts working again.
Clear (0)
symSCSI10 (115)
115
This event occurs when a SCSI device
swapped by another SCSI device. This
event is generated even if the replaced
device is identical.
Clear (0)
symSCSI11 (116)
116
This event occurs when a SMART event
occurs in the SCSI device.
Major (4)
symSCSI12 (117)
117
This event occurs when an internal error
occurs.
Minor (3)
Virtual Connect Module MIB (vc-module-mib)
Trap types
Rules file
Description
Netcool
severity
vcModPortInputUtilizationUp
(11)
11
This event occurs when the port input
utilization rate exceeds high threshold.
Minor(3)
vcModPortInputUtilizationDown
(12)
12
This event occurs when the port input
utilization rate drops below low
watermark.