Appendix B: HP SNMP events 78
Trap types
Rules file
Description
Netcool
severity
respond.
sCellEventTrap-06-
02(13601538)
13601538
This event occurs when a physical disk
drive reports a check condition error.
Clear (0)
sCellEventTrap-06-
03(13601539)
13601539
This event occurs when an exchange sent
to a physical disk drive or another
HSV300 controller through the mirror port
or a Fibre Channel port times out.
Minor(3)
sCellEventTrap-06-
04(13601540)
13601540
This event occurs when work is
unexpectedly sent to this HSV300
controller by a physical disk drive or
another HSV300 controller.
Minor(3)
sCellEventTrap-06-
05(13601541)
13601541
This event occurs when work is sent to a
physical disk drive or another HSV300
controller through the mirror port but the
controller does not respond.
Minor(3)
sCellEventTrap-06-
07(13601543)
13601543
This event occurs when a Target
Discovery Service Descriptor exchange
sent to a physical disk drive times out.
Minor(3)
sCellEventTrap-06-
08(13601544)
13601544
This event occurs when an excessive
number of link errors are detected on an
HSV300 controller Fibre Channel port.
This informational event is triggered by
the occurrence of an excessive number of
Tachyon chip link status errors detected
within a particular link status error type.
Clear (0)
sCellEventTrap-06-
09(13601545)
13601545
This event occurs when a physical disk
drive reports failure prediction threshold
exceeded errors.
Clear (0)
sCellEventTrap-06-
0a(13601546)
13601546
This event occurs when a physical disk
drive reports numerous check condition
errors.
Clear (0)
sCellEventTrap-06-
0b(13601547)
13601547
This event occurs when a non-data
exchange sent to physical disk drive has
timed out.
Minor(3)
sCellEventTrap-06-
0c(13601548)
13601548
This event occurs when a loop switch is
detected on a Fibre Channel port.
Clear (0)
sCellEventTrap-06-
1a(13601562)
13601562
This event occurs when a physical disk
drive exceeds its soft error threshold.
Clear (0)
sCellEventTrap-06-
1c(13601564)
13601564
This event occurs when an outbound
frame targeted to a physical disk drive
times out.
Minor(3)
sCellEventTrap-06-
1d(13601565)
13601565
This event occurs when a Fibre Channel
exchange to a physical disk drive is
retried
Minor(3)
sCellEventTrap-06-
1e(13601566)
13601566
This event occurs when an HSV300
controller has detected only one port of a
Fibre Channel device.
Critical(5)
sCellEventTrap-06-
13601567
This event occurs when a previously
reported Fibre Channel device with only
Clear (0)