HP Insight Management for Tivoli User Manual
Page 21
Appendix B: HP SNMP events 21
Trap types
Rules file
Description
Netcool
severity
cpqCrDiskAvailableTrap (13) 13
This event occurs when a disk drive
has been physically added or set to
the Available state.
Clear (0)
cpqCrDiskSpareTrap (14)
14
This event occurs when a disk drive
has been set to Spare status from
Available and can be used in a
RAID 1, RAID 1+0 or RAID 5 logical
disk should a member device fail in
one of those RAIDsets.
Clear (0)
cpqCrEMUNormalTrap (15)
15
This event occurs when the overall
condition of the primary enclosure
has returned to normal.
Clear (0)
cpqCrEMUFanFailureTrap
(16)
16
This event occurs when one of the
cooling fans in the primary
enclosure has failed.
Critical (5)
cpqCrEMUFanInformationTrap
(17)
17
This event occurs when the cooling
fan in the primary enclosure has
recovered.
Clear (0)
cpqCrEMUPowerSupplyFailur
eTrap (18)
18
This event occurs when one of the
power supplies in the primary
enclosure has failed.
Critical (5)
cpqCrEMUPowerSupplyInform
ationTrap (19)
19
This event occurs when the power
supply in the primary enclosure has
recovered.
Clear (0)
cpqCrExpCabFanFailureTrap
(20)
20
This event occurs when one of the
cooling fans in the expansion
cabinet has failed.
Critical (5)
cpqCrExpCabFanInformationT
rap (21)
21
This event occurs when the cooling
fan in the expansion cabinet has
returned to a normal state.
Clear (0)
cpqCrExpCabPowerSupplyFai
lureTrap (22)
22
This event occurs when one of the
power supplies in the expansion
cabinet has failed.
Critical (5)
cpqCrEMUTemperatureWarni
ngTrap (23)
23
This event occurs when the
temperature in the primary
enclosure has triggered a Warning
condition detected by the controller.
Minor (3)
cpqCrEMUTemperatureCritical
Trap (24)
24
This event occurs when the
temperature in the primary
enclosure has triggered a Critical
condition detected by the controller.
Major (4)
cpqCrEMUTemperatureInform
ationTrap (25)
25
This event occurs when the
temperature in the primary
enclosure has returned to normal.
Clear (0)
cpqCrExpCabTemperatureMin
or (3)Trap (26)
26
This event occurs when the
temperature in the expansion
cabinet has triggered a Minor (3)
condition detected by the controller.
Minor (3)