beautypg.com

HP Insight Management for Tivoli User Manual

Page 84

background image

Appendix B: HP SNMP events 84


Trap types

Rules file

Description

Netcool

severity

02(13602306)

volume has changed.

sCellEventTrap-09-

03(13602307)

13602307

This event occurs when the state of a

logical disk has changed.

Clear (0)

sCellEventTrap-09-

04(13602308)

13602308

This event occurs when an HSV300

controller transitiond to the NORMAL state
because the system is no longer
inoperative.

Clear (0)

sCellEventTrap-09-

05(13602309)

13602309

This event occurs when the state of a

battery assembly changes.

Clear (0)

sCellEventTrap-09-

06(13602310)

13602310

This event occurs when a volume

transitions to MISSING state.

Critical(5)

sCellEventTrap-09-

07(13602311)

13602311

This event occurs when a Fibre Channel

port transitions to the NORMAL state.

Clear (0)

sCellEventTrap-09-

08(13602312)

13602312

This event occurs when a Disk Group

occupancy alarm level threshold is
reached.

Minor(3)

sCellEventTrap-09-
09(13602313)

13602313

This event occurs when the resource
availability state of a volume transitions to

the SUFFICIENT state.

Clear (0)

sCellEventTrap-09-

0a(13602314)

13602314

This event occurs when the data

availability state of an internal logical
disk transitions to the NORMAL state.

Clear (0)

sCellEventTrap-09-

0c(13602316)

13602316

This event occurs when a snapclone

logical disk completes the unsharing
operation.

Clear (0)

sCellEventTrap-09-

0d(13602317)

13602317

This event occurs when the state of the

quorum disk flag of a volume changes.

Clear (0)

sCellEventTrap-09-

0e(13602318)

13602318

This event occurs when the temperature

trip point for a temperature sensor located
within an HSV300 controller is reached.

Critical(5)

sCellEventTrap-09-0f

(13602319)

13602319

This event occurs when the temperature

within an HSV300 controller approaches
its trip point.

Minor(3)

sCellEventTrap-09-

11(13602321)

13602321

This event occurs when an HSV300

controller blower 1 is present.

Clear (0)

sCellEventTrap-09-

12(13602322)

13602322

This event occurs when an HSV300

controller blower 1 is running slower than
the lowest acceptable speed.

Critical(5)

sCellEventTrap-09-

13(13602323)

13602323

This event occurs when a voltage sensor

reports a voltage that is out of range.

Critical(5)

sCellEventTrap-09-
14(13602324)

13602324

This event occurs when a volume
transitions to the FAILED state.

Critical(5)

sCellEventTrap-09-
15(13602325)

13602325

This event occurs when an HSV300

controller fails as a result of the system
becoming inoperative.

Critical(5)

sCellEventTrap-09-

16(13602326)

13602326

This event occurs when the temperature

within an HSV300 controller returns to its

Clear (0)