HP Insight Management for Tivoli User Manual
Page 84
Appendix B: HP SNMP events 84
Trap types
Rules file
Description
Netcool
severity
02(13602306)
volume has changed.
sCellEventTrap-09-
03(13602307)
13602307
This event occurs when the state of a
logical disk has changed.
Clear (0)
sCellEventTrap-09-
04(13602308)
13602308
This event occurs when an HSV300
controller transitiond to the NORMAL state
because the system is no longer
inoperative.
Clear (0)
sCellEventTrap-09-
05(13602309)
13602309
This event occurs when the state of a
battery assembly changes.
Clear (0)
sCellEventTrap-09-
06(13602310)
13602310
This event occurs when a volume
transitions to MISSING state.
Critical(5)
sCellEventTrap-09-
07(13602311)
13602311
This event occurs when a Fibre Channel
port transitions to the NORMAL state.
Clear (0)
sCellEventTrap-09-
08(13602312)
13602312
This event occurs when a Disk Group
occupancy alarm level threshold is
reached.
Minor(3)
sCellEventTrap-09-
09(13602313)
13602313
This event occurs when the resource
availability state of a volume transitions to
the SUFFICIENT state.
Clear (0)
sCellEventTrap-09-
0a(13602314)
13602314
This event occurs when the data
availability state of an internal logical
disk transitions to the NORMAL state.
Clear (0)
sCellEventTrap-09-
0c(13602316)
13602316
This event occurs when a snapclone
logical disk completes the unsharing
operation.
Clear (0)
sCellEventTrap-09-
0d(13602317)
13602317
This event occurs when the state of the
quorum disk flag of a volume changes.
Clear (0)
sCellEventTrap-09-
0e(13602318)
13602318
This event occurs when the temperature
trip point for a temperature sensor located
within an HSV300 controller is reached.
Critical(5)
sCellEventTrap-09-0f
(13602319)
13602319
This event occurs when the temperature
within an HSV300 controller approaches
its trip point.
Minor(3)
sCellEventTrap-09-
11(13602321)
13602321
This event occurs when an HSV300
controller blower 1 is present.
Clear (0)
sCellEventTrap-09-
12(13602322)
13602322
This event occurs when an HSV300
controller blower 1 is running slower than
the lowest acceptable speed.
Critical(5)
sCellEventTrap-09-
13(13602323)
13602323
This event occurs when a voltage sensor
reports a voltage that is out of range.
Critical(5)
sCellEventTrap-09-
14(13602324)
13602324
This event occurs when a volume
transitions to the FAILED state.
Critical(5)
sCellEventTrap-09-
15(13602325)
13602325
This event occurs when an HSV300
controller fails as a result of the system
becoming inoperative.
Critical(5)
sCellEventTrap-09-
16(13602326)
13602326
This event occurs when the temperature
within an HSV300 controller returns to its
Clear (0)