HP Insight Management for Tivoli User Manual
Page 101
![background image](/manuals/398556/101/background.png)
Appendix B: HP SNMP events 101
Trap types
Rules file
Description
Netcool
severity
34(13603380)
missing. This might affect the drive
enclosure air flow and cause an over
temperature condition. The operational
power supply automatically shuts down
after a short time, thereby disabling the
drive enclosure. This condition remains
active until either the problem is
corrected, or the operational power
supply shuts down, whichever occurs first.
sCellEventTrap-0d-
35(13603381)
13603381
This event occurs when a drive enclosure
power supply component fails.
Critical(5)
sCellEventTrap-0d-
47(13603399)
13603399
This event occurs when a drive enclosure
fan module is not operating properly. This
might affect the drive enclosure air flow
and cause an over temperature condition.
A single fan operating at high speed can
provide sufficient air flow to cool an
enclosure. Operating an enclosure at
temperatures approaching an
overheating threshold can damage
elements and might reduce the mean time
before failure of a specific element.
Critical(5)
sCellEventTrap-0d-
4b(13603403)
13603403
This event occurs when a drive enclosure
fan module is improperly installed or
missing. This affects the drive enclosure
air flow and can cause an over
temperature condition.
Critical(5)
sCellEventTrap-0d-
5b(13603419)
13603419
This event occurs when a drive enclosure
temperature sensor out of range condition
is reported by one of the drive enclosure
link modules.
Minor(3)
sCellEventTrap-0d-
5f(13603423)
13603423
This event occurs when the temperature of
Enclosure Link Module temperature sensor
is at a critical level. The operational
power supplies automatically shuts down
the drive bays after a short period of
time, thereby disabling the drive
enclosure. This condition remains active
until either the problem is corrected, or
the operational power supplies shut
down, whichever occurs first. For the
temperature threshold values, see the HSV
element manager GUI.
Critical(5)
sCellEventTrap-0d-
8d(13603469)
13603469
This event occurs when a drive enclosure
transceiver error is detected.
Critical(5)
sCellEventTrap-0d-
dd(13603549)
13603549
This event occurs when a drive enclosure
I/O module error occurs.
Critical(5)
sCellEventTrap-0d-
de(13603550)
13603550
This event occurs when a drive enclosure
I/O module is not communicating with
the other I/O module.
Minor(3)
sCellEventTrap-0d-
13603568
This event occurs when the status changes Clear (0)