HP Insight Management for Tivoli User Manual
Page 56
Appendix B: HP SNMP events 56
Trap types
Rules file Description
Netcool
severity
cpqRPMTrapCMCLockset1Locke
d(10114)
10114
This event occurs when a CMC device
reports lockset 1 is locked.
Clear (0)
cpqRPMTrapCMCLockset2Unloc
ked(10116)
10116
This event occurs when a CMC device
reports lockset 2 is unlocked.
Clear (0)
cpqRPMTrapCMCLockset2Failed
ToLock(10117)
10117
This event occurs when a CMC device
reports lockset 2 fails to lock.
Major (4)
cpqRPMTrapCMCLockset2Error(
10118)
10118
This event occurs when a CMC device
reports an error with lockset 2.
Major (4)
cpqRPMTrapCMCLockset2Locke
d(10119)
10119
This event occurs when a CMC device
reports lockset 2 is locked.
Clear (0)
cpqRPMTrapCMCLockset1Norm
al(10134)
10134
This event occurs when a CMC device
reports lockset 1 is normal.
Clear (0)
cpqRPMTrapCMCLockset2Norm
al(10135)
10135
This event occurs when a CMC device
reports lockset 2 is normal.
Clear (0)
cpqRPMTrapUPSInputVoltageBel
owMin (20001)
20001
This event occurs when a UPS device is
reporting input voltage below minimum
threshold.
Major (4)
cpqRPMTrapUPSInputVoltageAb
oveMax (20002)
20002
This event occurs when a UPS device
reports input voltage above maximum
threshold.
Major (4)
cpqRPMTrapUPSInputVoltageNo
rmal (20003)
20003
This event occurs when a UPS device
reports input voltage is normal.
Clear (0)
cpqRPMTrapUPSOutputVoltageB
elowMin (20011)
20011
This event occurs when a UPS device
reports output voltage is below minimum
threshold.
Minor (3)
cpqRPMTrapUPSOutputVoltageA
boveMax (20012)
20012
This event occurs when a UPS device
reports output voltage above maximum
threshold.
Minor (3)
cpqRPMTrapUPSOutputOverloa
d (20014)
20014
This event occurs when a UPS device
reports an overload condition.
Major (4)
cpqRPMTrapUPSOutputOverloa
dCleared (20015)
20015
This event occurs when a UPS device
reports an overload condition is cleared.
Clear (0)
cpqRPMTrapUPSBatteryDepleted
(20022)
20022
This event occurs when a UPS device has a
depleted battery.
Major (4)
cpqRPMTrapUPSBatteryLevelNor
mal (20023)
20023
This event occurs when a UPS device
reports battery level is normal.
Clear (0)
cpqRPMTrapUPSOnBypass
(20032)
20032
This event occurs when a UPS device is
bypassed.
Minor (3)
cpqRPMTrapUPSTemperatureLo
w (20101)
20101
This event occurs when a UPS device
reports temperature below minimum
threshold.
Major (4)
cpqRPMTrapUPSTemperatureHig
h (20102)
20102
This event occurs when a UPS device
reports temperature above maximum
threshold.
Major (4)
cpqRPMTrapUPSTemperatureNo
rmal (20103)
20103
This event occurs when a UPS device
reports temperature is normal.
Clear (0)