Appendix B: HP SNMP events 103
Trap types
Rules file
Description
Netcool
severity
sCellEventTrap-0e-
1e(13603614)
13603614
This event occurs when there is an initial
temperature within an HSV300 controller.
Clear (0)
sCellEventTrap-0e-
1f(13603615)
13603615
This event occurs when the temperature
within an HSV300 controller returns to
normal.
Clear (0)
sCellEventTrap-0e-
20(13603616)
13603616
This event occurs when the temperature
within an HSV300 controller becomes too
hot.
Minor(3)
sCellEventTrap-0e-
21(13603617)
13603617
This event occurs when the temperature
within an HSV300 controller is too hot.
Critical(5)
sCellEventTrap-0e-
22(13603618)
13603618
This event occurs when the Power supply
is in its initial status.
Clear (0)
sCellEventTrap-0e-
23(13603619)
13603619
This event occurs when the Power supply
is inserted.
Clear (0)
sCellEventTrap-0e-
24(13603620)
13603620
This event occurs when the Power supply
is removed.
Critical(5)
sCellEventTrap-0e-
25(13603621)
13603621
This event occurs when the Power supply
status changes.
Clear (0)
sCellEventTrap-0e-
26(13603622)
13603622
This event occurs when the Power supply
malfunctions or there is a lost AC
connection.
Critical(5)
sCellEventTrap-0e-
2b(13603627)
13603627
This event occurs when an HSV300
controller is in its initial status.
Clear (0)
sCellEventTrap-0e-
2c(13603628)
13603628
This event occurs when an HSV300
controller is inserted.
Clear (0)
sCellEventTrap-0e-
2d(13603629)
13603629
This event occurs when an HSV300
controller is removed.
Critical(5)
sCellEventTrap-0e-
2e(13603630)
13603630
This event occurs when an HSV300
controller is operating normally.
Clear (0)
sCellEventTrap-0e-
2f(13603631)
13603631
This event occurs when an HSV300
controller malfunctions.
Critical(5)
sCellEventTrap-0e-
34(13603636)
13603636
This event occurs when an HSV300
controller status changes.
Clear (0)
sCellEventTrap-0e-
35(13603637)
13603637
This event occurs when an HSV300
controller operation is degraded.
Minor(3)
sCellEventTrap-0e-
36(13603638)
13603638
This event occurs when there is a
malfunction of link between HSV300
controllers through their system data
collectors.
Critical(5)
sCellEventTrap-0e-
37(13603639)
13603639
This event occurs when a Management
module is in its initial status.
Clear (0)
sCellEventTrap-0e-
38(13603640)
13603640
This event occurs when the Management
module is inserted.
Clear (0)
sCellEventTrap-0e-
39(13603641)
13603641
This event occurs when the Management
module is removed.
Critical(5)
sCellEventTrap-0e-
13603642
This event occurs when the Management
Clear (0)