Delete a Block

The example below illustrates how to delete a subnet block. Type the
delete block command with the block ID (block ID is 1 in the
example).

1. Use the show block command to identify the block to be deleted.

HP SA7150> show block

-----------

blocks :

-----------

(1) block 10.1.2.1 255.255.255.255 20.1.2.1

255.255.255.255 80 0xffff

-----------

2. Use the delete block command followed by the block ID to

delete the block.

HP SA7150> delete block 1

Failure Conditions, Fail-safe, and Fail-through

During a failure condition unprocessed data can either pass through
the SA7150 or not, depending on whether Fail-safe or Fail-through
mode is enabled. The Fail-through switch is by default in Fail-safe
mode, meaning that during a failure no data packets will pass from
one side of the SA7150 to the other. For details, see “Failure/Bypass
Modes” in Appendix B.