beautypg.com

Ovl: overload alarm, Alarm modifiers and messages, Extended data – HP e-CommerceXML Accelerator sa7150 User Manual

Page 147: Ovl alarm cli commands

background image

C H A P T E R 7

Alarm Types

137

OVL: Overload
Alarm

When enabled, an alarm is issued upon occurrence of overloads
resulting in spills or throttles during the current user-configured
alarm period (5 to 65000 seconds, default: 15 seconds).

WARNING: This alarm
indicates loss of encryp-
tion/decryption. (Normal
SSL operation resumes
when the alarm ceases.)

Format:

A:mm/dd/yyyy hh:mm:ss:OVL:SPIL|THRT:XXX:

/*message*/

Where:

A: identifies the message as an alarm.

mm/dd/yyyy hh:mm:ss: is the timestamp.

OVL: identifies the message as an Overload

Alarm.

Alarm Modifiers and Messages

SPIL: indicates overload resulting in a

spill. Message: Spill mode.

THRT: indicates overload resulting in a

throttle. Message: Throttle mode.

Extended Data

XXX: An integer value indicating the total

number of overload events that occurred

during the most recent alarm period.

OVL Alarm CLI Commands

To set Overload Alarm time window:

HP SA7150> set ovl_window (Range:

5-65000, default: 15)

To display Overload Alarm time window:

HP SA7150> show ovl_window

Examples:

HP SA7150> set ovl_window 10

HP SA7150> show ovl_window

Check for overload conditions [secs]: 10