NOTE:

The following metrics can be added only when an array is selected in the Array/Group drop-down

box:
• SM CHIP Bus/FBus Hi Util
• SM ACP Bus/FBus Lo Util
• CM CHIP Bus/MBus Hi Util
• CM ACP Bus/MBus Lo Util
• Cache Usage
• Cache Write Pending Usage
• Cache Sidefile Usage

NOTE:

If you select an item in the Metric drop-down box, pertaining to volumes, the CU drop-down menu

displays. The CU drop-down menu displays LDEVs by CU. Selecting a CU displays a list of LDEVs

belonging to that CU in the Resources list box.

Use the Alarm Type drop-down menu to specify the alarm type, either Level or Trend. For a

description of level and trend alarm types, see

Level and Trend alarm types

.

Specify the sample count. This feature is currently unavailable and will be implemented in a

future release.

Sort the list shown in the Sort by drop-down menu by DKC, items, or metric

Add or remove alarms

Abandon all changes that are made in this screen, prior to committing the changes and saving

the data to the database

Level and Trend alarm types

Two alarm types are available for charting alarms: Level and Trend.
When a level-type alarm is selected, an alarm is triggered whenever a specified threshold is exceeded.

For example, if the settings call for an alarm to be triggered at 5,000 IOs, then you receive notification if

the IOs reach the 5,000 level.
When a trend-type alarm is specified, an alarm is triggered whenever a specified rate of change occurs.

In this type of alarm, the rate of change, rather than a particular value, triggers the alarm. When a

trend-type alarm is charted, the slope of the line that appears is generated from an average of the data

points. For example, if the IO rate shifts from 4,000 to 2,000, an alarm triggered.
For level and trend alarms, a recovery alarm is also triggered whenever a specified threshold or rate of

change recovers within acceptable levels. For recovery alarms, the subject line of the email notification is

appended with “Good Information Alarm.” For more information on disabling recovery alarms, see HP

StorageWorks Performance Advisor XP Software installation guide.
Use the Edit Schedule/Trend dialog box to specify the desired times and duration as shown in

Edit

Schedule/Trend dialog box

.

HP StorageWorks Performance Advisor XP Software user guide