beautypg.com

Columns, Alarm history screen columns – HP XP Performance Advisor Software User Manual

Page 51

background image

Columns

Table 15 Alarm History screen columns

Component

Description

Array Type

The following types are arrays are available: XP512,

XP48, XP256, XP128, XP1024, XP10000, XP12000,

XP24000, XP20000 and Unknown.

DKC/Grp

A list of the arrays, or the name of the group that

generate alarms.

Email Status SNMP Status

These fields show whether the alarm information

sent by Email or SNMP was successful, or if

errors occurred. If errors occurred, a list of

values is displayed for the error type(s). This

list of values ranges from 1 to 6.0: Successful

Send (0 also displays when no send is needed)

1: Alarm Exception (while formatting raw data)

2: General Exception (while formatting raw data)

3: Courier Exception (while sending formatted data)

4: General Exception (while sending formatted data)

5: Error During Results Calculation

6: Uninitialized Result (error before formatting stage)

The email address refers to the email address of

the management station where the alarm-event

information is dispatched.

ID

The ID number given to the array that is associated

with the alarm. Provides an index for alarm events.

NOTE:

An asterisk (*) next to the ID indicates a recovery

alarm. A recovery alarm is triggered whenever

a specified threshold or rate of change recovers

within acceptable levels.

Level

A threshold level of 1, 2, or 3 is specified for each

alarm. For more information about threshold levels,

see

Alarm Configuration

.

Metric Category

A list of the metric categories associated with the

array that you are monitoring.

Metric Value

The value of the metric category for which an alarm

is generated.

Script Status

The path name of the script file.

Threshold

The performance metric data value at which an

instance of the alarm becomes active.

Time Dispatched

The time when the alarm was sent out.

Time Posted

The time when the alarm was initially posted.

Time Updated

The time when modifications were last made to the

alarm.

Type

The alarm type, whether level or trend.

Value

The value established at the management station

when an alarm crosses a threshold.

VPO Status

The VPO error status number.

HP StorageWorks Performance Advisor XP Software user guide

51