Set session timeout, Set user access, Set user contact – HP Onboard Administrator User Manual
Page 29

User account commands 29
o
When in FIPS Mode OFF, the character set includes all printable characters. When in FIPS Mode
ON/DEBUG, the password must contain at least one character from three of the four types of
characters. The four types are upper-case, lower-case, numeric, and non-alphanumeric.
SET SESSION TIMEOUT
•
Command:
SET SESSION TIMEOUT
•
Description:
Sets the number of minutes before inactive sessions are removed. The default setting is 1440.
•
Access level/ Bay level:
OA administrator
•
Restriction:
Valid session timeout values range from 10 to 1440 minutes (24 hours).
SET USER ACCESS
•
Command:
SET USER ACCESS "
•
Description:
Sets the user access level. Additionally, use the ASSIGN command to give the user access rights to the
Onboard Administrator, server bays, and interconnect bays.
•
Access level/Bay level:
OA administrator
•
Restrictions:
None
SET USER CONTACT
•
Command:
SET USER CONTACT ["
•
Description:
Sets the contact information field for the user. If there is no
contact information of the user who executed the command.
•
Access level/Bay level:
o
All users can modify their own contact information.
o
The OA administrator can modify all users.
•
Restrictions:
o
The
and includes all alphanumeric characters, the dash, the underscore, and spaces.
o
The default contact information is blank.