Set enclosure name, Set enclosure part_ number, Set enclosure pdu_type – HP Onboard Administrator User Manual
Page 116

Enclosure management commands 116
The
dash (-) characters.
SET ENCLOSURE NAME
•
Command:
SET ENCLOSURE NAME "
•
Description:
o
Changes the enclosure name
o
The default enclosure name is the mid-plane serial number
•
Access level/Bay level:
OA administrator, OA operator
•
Restrictions:
The
and dash (-) characters.
SET ENCLOSURE PART_ NUMBER
•
Command:
SET ENCLOSURE PART_NUMBER "
•
Description:
Sets the part number of the enclosure
•
Access level/Bay level:
OA administrator
•
Restrictions:
Must be 10 characters in length and the first character must be a digit. Acceptable characters are all
alphanumeric and the dash (-).
SET ENCLOSURE PDU_TYPE
•
Command:
SET ENCLOSURE PDU_TYPE {1|2|3|4|5}
•
Description:
Sets the enclosure PDU type to:
o
1=Single-phase
o
2=Three-phase
o
3=Three-phase, international
o
4=DC Power Input Module
o
5=Single phase IPD
•
Access level/Bay level: