Show enclosure power_cap, Show enclosure power_cap_bays_to_exclude – HP Onboard Administrator User Manual
Page 203

Enclosure Dynamic Power Cap commands 203
If you have previously specified bays to exclude, using this command again replaces that specification
rather than augmenting it.
•
Access level/Bay level:
OA administrator, OA operator
•
Restriction:
You can exclude no more than one fourth of the bays.
SHOW ENCLOSURE POWER_CAP
•
Command:
SHOW ENCLOSURE POWER_CAP
•
Description:
Displays the current Enclosure Dynamic Power Cap in watts.
•
Access level/Bay level:
All
•
Restriction:
None
•
Example:
OA-0018FE27577> SHOW ENCLOSURE POWER_CAP
Enclosure Dynamic Power Cap:
Disabled
Derated Circuit Capacity:
Disabled
Rated Circuit Capacity:
Disabled
Allowable Enclosure Dynamic Power Cap:
3123 - 7676 Watts AC
Allowable Derated Circuit Capacity:
3123 - 7676 Watts AC
Allowable Rated Circuit Capacity:
3428 - 7676 Watts AC
SHOW ENCLOSURE
POWER_CAP_BAYS_TO_EXCLUDE
•
Command:
SHOW ENCLOSURE POWER_CAP_BAYS_TO_EXCLUDE
•
Description:
Displays the bays in the enclosure that are exempt from the Enclosure Dynamic Power Cap.
•
Access level/Bay level:
All
•
Restriction:
None
•
Example:
OA-0018FE27577F> show enclosure power_cap_bays_to_exclude
Bays opted out: None