KROHNE ALTOSONIC V EN User Manual
Page 98
ALTOSONIC V
Operating Manual rev02 E
7.30850.34.00
Page 98 of 106
10.4 Extra batching options
10.4.1 Air buoyancy correction
If this option is enabled, at the end of the batch the Air buoyancy correction is calculated and possible
printed on the ticket (registers 527…529).
CLNT0300.DAT Excerpt
10.4.2 Batching without printer
The option to use batching without use of the printer. The tickets are saved in the UFP. If a printer is
connected, the tickets will be printed. If there is no printer available, no alarm or window swapping will
take place.
12.05 Modbus_control c=#2 //0=No Control batching through Modbus
//1=Control batching through Modbus
//2=as 0 with no printer alarm
//3=as 1 with no printer alarm
19 [WEIGHT OF STANDARD (batch) VOLUME IN AIR (AirBuoyancy correction)]
The weight (in air) is calculated as follows:
W.I.A. = Volume(15) * ( Density(15) + AirBuoyancy ) * Factor + Offset
[kg] = [m3] * ( [kg/m3] + [kg/m3] )
Where the * Factor + Offset part is to be able to influence the unit of
the W.I.A. Ie. a factor of 0.001 will give the W.I.A. in metric tons [t].
19.01 WeightInAir
=#0
//[0..1] 0=OFF, 1=ON
19.02 AirBuoyancy
=#-1.10
//[-100..100] Air Buoyancy number [kg/m3]
19.03 Factor
=#0.001
//19.3 and 19.4 are for calculating the desired
19.04 Offset
=#0.000
//unit by utilising: Y = X * Factor + Offset