ALTOSONIC V

Operating Manual rev02 E

7.30850.34.00

Page 64 of 106

612

Batch 1 alarm: measured Densito pressure out of range

B

613

Batch 1 alarm: measured Densito Density out of range

B

614

Batch 1 alarm: measured Standard Density out of range

B

615

Batch 1 alarm: measured External viscosity out of range

E

616

Batch 1 alarm: override Body temperature applied

B

617

Batch 1 alarm: override Proces temperature applied

B

618

Batch 1 alarm: override External Prove temperature applied

E

619

Batch 1 alarm: override Densito temperature applied

B

620

Batch 1 alarm: override Proces pressure applied

B

621

Batch 1 alarm: override External Prove pressure applied

E

622

Batch 1 alarm: override Densito pressure applied

B

623

Batch 1 alarm: override Densito Density applied

B

624

Batch 1 alarm: override Standard Density applied

E

625

Batch 1 alarm: override External viscosity applied

B

626

…627 reserved

Configuration API etc

Operation

701

Calculation method: Only proces flow, Standard volume/mass by API standards, mass

measurement by proces density

B

702

Temperature standard in value

B

703

Density standard by: fill in manually, calculated from densito meter density, on AD / Modbus input

B

704

Fluid type: crude, gasoline, trans.area, jetgroup, fuel oil, free fill

B

705

API correction factor K0

B

706

API correction factor K1

B

707

API correction factor K2

B

708

..749 reserved

750

Print Modbus float32, Modbus address (NotModicon compatible) 7095 (1751) or 7100 (2751)

E

751

Print Modbus float32, Modbus address (NotModicon compatible) 7096 (1752) or 7101 (2752)

E

752

Print Modbus float32, Modbus address (NotModicon compatible) 7097 (1753) or 7102 (2753)

E

753

Print Modbus float32, Modbus address (NotModicon compatible) 7098 (1754) or 7103 (2754)

E

754

Print Modbus float32, Modbus address (NotModicon compatible) 7099 (1755) or 7104 (2755)

E

755

Print Modbus float32, Modbus address (NotModicon compatible) (7095 – 7100) (with 1756)
(7100 – 7095) (with 2756)

E

756

Print Modbus float32, Modbus address (NotModicon compatible) (7096 – 7101) (with 1757)

(7101 – 7096) (with 2757)

E

757

Print Modbus float32, Modbus address (NotModicon compatible) (7097 – 7102) (with 1758)

(7102 – 7097) (with 2758)

E

758

Print Modbus float32, Modbus address (NotModicon compatible) (7098 – 7103) (with 1759)

(7103 – 7098) (with 2759)

E

759

Print Modbus float32, Modbus address (NotModicon compatible) (7099 – 7104) (with 1760)

(7104 – 7099) (with 2760)

E

760

..799 reserved

Security

Operation

801

CRC checksum on data set UFS

B

802

CRC checksum on data set UFP

B

803

CRC checksum on data set DAT

B

804

CRC checksum on Executable

B

805

..999 reserved


Operation B: Basic operations

Operation E: Extended operations