6.10 During batch
During a batch the restrictions are handled as the installed BATCHING_ON level prescribes.

Files with all alarm times, totalisers, and batch averages are saved every 12 seconds to a SRAM disk

(or industrial compact flash with static and dynamic wear levelling) in dual files.

Sequentially saving it each time in a different file (file1 or file2). So when the power is turned of during a

file-save causing the file to be corrupted, the previously saved dual file is used at start-up to load

previously saved alarm times, totalisers, and batch averages.

6.10.1 Reading / Printing previous batch ticket

During a batch it is possible to read and print a previous batch ticket

From Main window to Batch Control window by F7 and then Function Key F2 for reading previous

batch ticket

Explanation Function keys:

F1

: Back to Main Window

F2

: Return to Batch Control window

F3

: Upload “Ticket to read “

F4…F7

: Change “Ticket to read” number within the limits of “Tickets available”