beautypg.com

KROHNE ALTOSONIC V EN User Manual

Page 65

background image

ALTOSONIC V

Operating Manual rev02 E

7.30850.34.00

Page 65 of 106

6.3.1

Special characters for printer control:

Special characters for printer control start with a 3.

The so called escape codes for printer control can be inserted into the Ticket Layout

Examples:

~3007@

Printer sounds a bel

~3012@

Formfeed

~3027@~3067@~3000@~30xx@

Set page length in inch in ~30xx@: xx=1…22

~3027@~3067@~3000@~3xxx@

Set page length in lines in ~3xxx@: xx=1…127

~3027@~3087@~3049@

Select double sized characters

~3027@~3087@~3048@

Cancel double sized characters

~3027@~3071@

Select double strike printing

~3027@~3072@

Cancel double strike printing

~3027@~3052@

Select italic characters

~3027@~3053@

Cancel italic characters

~3027@~3054@

Cancel italic characters

~3027@~3057@

Enable paper out sensor

~3027@~3056@

Disable paper out sensor

6.4

Initial batch set-up

The initial batch set-up is by initialisation file CLNT0300.dat file under section 12:

\


There are 4 modes for Batch configuration:

BATCHING

ON

Start stop batch
permission

Confirmation asked
on batch settings

API settings during
batch possible

0

Batch mode disabled

-------

------

1

Only at zero flow

conditions

Yes

No

2

At all flowing conditions

Yes

No

12
Only in use when a Epson Serial Printer according DIN66258 standard
is connected.
Note that in the HSET0300.UFP file (for hardware setup) the following data
must be set:
-1.4 Location_stat must be enabled (saving of status)
-1.8 Location_tic must be a disk with enough storage capacity

12.1 BATCHING_ON c=#2

//0=Internal batching disabled

//Manual batching modes:

//1=Enable Batching (start stop at zero flow)
//2=Enable Batching (start stop at all flows)

//Continuous piipe line modes

//3=Enable Batching: (Automatic)

//4=Enable Batching: (No Reset,possibly forced reset)

//If enabled then automatic initialize printer
12.2 Max_tickets c=#100

//Maximum number of last tickets saved 10..100000

//depending on disk space (see Location_tic above)
12.3 Hour_start c=#10

//Start hour 0..23 for continous pipe line ticket

12.4 Hour_interval c=#1

//Interval hour 1..24 for continous pipe line ticket

//0=No tickets automatically, only on demand

12.5 Modbus_control c=#1

//0=No Control batching through modbus

//1=Control batching through modbus

//2=as 0 with no printer alarm on printer failure

//3=as 1 with no printer alarm on printer failure