beautypg.com

KROHNE ALTOSONIC V EN User Manual

Page 63

background image

ALTOSONIC V

Operating Manual rev02 E

7.30850.34.00

Page 63 of 106

406

Non resetable Standard Reverse Total

B

407

Non resetable Mass Totaliser

B

408

Non resetable Mass Forward Totaliser

B

409

Non resetable Mass Reverse Totaliser

B

410

..499 reserved

Batch Flow weighted averages

Operation

501

Batch 1 average temperature body

B

502

Batch 1 average temperature proces

B

503

Batch 1 average temperature proving external flow meter

E

504

Batch 1 average temperature densito meter

B

505

Batch 1 average pressure proces

B

506

Batch 1 average pressure proving external flow meter

E

507

Batch 1 average pressure densito meter

B

508

Batch 1 average density densito meter

B

509

Batch 1 average density standard

B

510

Batch 1 average External Viscosity kynematic

B

511

Batch 1 average Ctl (15°C to proces)

B

512

Batch 1 average Cpl (0 Bar to proces)

B

513

Batch 1 average Ctl (15°C to standard )

B

514

Batch 1 average Cpl (0 Bar to standard, always 1)

B

515

Batch 1 average Ctl (15°C to densito meter )

B

516

Batch 1 average Cpl (0 Bar to densito meter)

B

517

Batch 1 average Ctl (15°C to proving external flow meter)

B

518

Batch 1 average Cpl. (0 Bar to proving external flow meter)

B

519

Batch 1 average temperature standard

B

520

Batch 1 average density proces

B

521

Batch 1 average flow actual

B

522

Batch 1 average density proving external flow meter

E

523

Batch 1 average flow proving external flow meter

E

524

Batch 1 average Installed Kfactor proving external flow meter

E

525

Batch 1 found New Kfactor proving external flow meter

E

526

Batch 1 difference installed vs new found Kfactor external

E

527

Batch 1 Air Buoyancy correction: Air Buoyancy number CLNT0300.DAT item 19.02

E

528

Batch 1 Air Buoyancy correction: Calculated Liter Weight

E

529

Batch 1 Air Buoyancy correction: Calculated Weight in Air

E

530

…550 reserved

551

Batch1 : Lowest measured Temperature (for high viscosity applications )

B

552

Batch1 : Deviation % (worst case estimate due to batch alarms)

B

553

…599 Reserved

Batch alarms in seconds

Operation

601

Batch 1 alarm: General Flow 1-4 channels down

B

602

Batch 1 alarm: General Flow all channels down

B

603

Batch 1 alarm: calculation API group mismatch

B

604

Batch 1 alarm: system runtime alarm occurred

B

605

Batch 1 alarm: real time profile out of range when used

B

606

Batch 1 alarm: measured Body temperature out of range

B

607

Batch 1 alarm: measured Proces temperature out of range

B

608

Batch 1 alarm: measured External Prove temperature out of range

E

609

Batch 1 alarm: measured Densito temperature out of range

B

610

Batch 1 alarm: measured Proces pressure out of range

B

611

Batch 1 alarm: measured External Prove pressure out of range

E