KROHNE ALTOSONIC V EN User Manual
Page 63

ALTOSONIC V
Operating Manual rev02 E
7.30850.34.00
Page 63 of 106
406
Non resetable Standard Reverse Total
B
407
Non resetable Mass Totaliser
B
408
Non resetable Mass Forward Totaliser
B
409
Non resetable Mass Reverse Totaliser
B
410
..499 reserved
Batch Flow weighted averages
Operation
501
Batch 1 average temperature body
B
502
Batch 1 average temperature proces
B
503
Batch 1 average temperature proving external flow meter
E
504
Batch 1 average temperature densito meter
B
505
Batch 1 average pressure proces
B
506
Batch 1 average pressure proving external flow meter
E
507
Batch 1 average pressure densito meter
B
508
Batch 1 average density densito meter
B
509
Batch 1 average density standard
B
510
Batch 1 average External Viscosity kynematic
B
511
Batch 1 average Ctl (15°C to proces)
B
512
Batch 1 average Cpl (0 Bar to proces)
B
513
Batch 1 average Ctl (15°C to standard )
B
514
Batch 1 average Cpl (0 Bar to standard, always 1)
B
515
Batch 1 average Ctl (15°C to densito meter )
B
516
Batch 1 average Cpl (0 Bar to densito meter)
B
517
Batch 1 average Ctl (15°C to proving external flow meter)
B
518
Batch 1 average Cpl. (0 Bar to proving external flow meter)
B
519
Batch 1 average temperature standard
B
520
Batch 1 average density proces
B
521
Batch 1 average flow actual
B
522
Batch 1 average density proving external flow meter
E
523
Batch 1 average flow proving external flow meter
E
524
Batch 1 average Installed Kfactor proving external flow meter
E
525
Batch 1 found New Kfactor proving external flow meter
E
526
Batch 1 difference installed vs new found Kfactor external
E
527
Batch 1 Air Buoyancy correction: Air Buoyancy number CLNT0300.DAT item 19.02
E
528
Batch 1 Air Buoyancy correction: Calculated Liter Weight
E
529
Batch 1 Air Buoyancy correction: Calculated Weight in Air
E
530
…550 reserved
551
Batch1 : Lowest measured Temperature (for high viscosity applications )
B
552
Batch1 : Deviation % (worst case estimate due to batch alarms)
B
553
…599 Reserved
Batch alarms in seconds
Operation
601
Batch 1 alarm: General Flow 1-4 channels down
B
602
Batch 1 alarm: General Flow all channels down
B
603
Batch 1 alarm: calculation API group mismatch
B
604
Batch 1 alarm: system runtime alarm occurred
B
605
Batch 1 alarm: real time profile out of range when used
B
606
Batch 1 alarm: measured Body temperature out of range
B
607
Batch 1 alarm: measured Proces temperature out of range
B
608
Batch 1 alarm: measured External Prove temperature out of range
E
609
Batch 1 alarm: measured Densito temperature out of range
B
610
Batch 1 alarm: measured Proces pressure out of range
B
611
Batch 1 alarm: measured External Prove pressure out of range
E