89

Parameter

Span frequency range

Return parameter

Returns the span and unit

Example

meas:span 10 mhz
Sets the span to 10MHz

Query Example

meas:span?
> 10000.0 kHz

meas:span:full

Set

Description

Sets the span to the full span.

Syntax

meas:span:full

Amplitude Commands

meas:refl:unit ............................................................................ 89

meas:refl .................................................................................... 89

meas:refl:unit

Set

Query

Description

Sets the reference level unit.

Syntax

meas:refl:unit {1|2|3}

Query Syntax

meas:refl:unit?

Parameter/
Return parameter

1

dBm

2

dBmV

3

dBuV

Query Example

Meas:refl:unit?
>1
The reference level units are dBm.

meas:refl

Set

Query

Description