beautypg.com

Limit line commands, Meas:ocbw:bw, Meas:ocbw:chpw – GW Instek GSP-730 User Manual User Manual

Page 100: Meas:lmtline:passfail

background image

GSP-730 User Manual

98

Syntax

meas:ocbw {on|off}

Query Syntax

meas:ocbw?

Parameter/
Return parameter

On

OCBW mode = on

Off

OCBW mode = off

Example

meas:ocbw on
Turns the OCBW function on.

meas:ocbw:bw?

Set

Query

Description

Returns the OCBW in kHz.

Query syntax

meas:ocbw:bw?

Return parameter

Returns the OCBW in kHz

Example

meas:ocbw:bw?
>4000kHz

meas:ocbw:chpw?

Set

Query

Description

Returns the channel power in the current unit.

Query syntax

meas:ocbw:chpw?

Return parameter

Returns the channel power

Example

meas:ocbw:chpw?
>-63.5

Limit Line Commands

meas:lmtline:passfail ............................................................... 98

meas:lmtline:on ........................................................................ 99

meas:lmtline:off ....................................................................... 99

meas:lmtline:passfail

Set

Query

Description

Turns the Pass/Fail test on/off or queries its state.