State and status information, In this appendix, Encryption engine security processor (sp) states – Brocade Fabric OS Encryption Administrator’s Guide Supporting HP Secure Key Manager (SKM) and HP Enterprise Secure Key Manager (ESKM) Environments (Supporting Fabric OS v7.2.0) User Manual
Page 311: Appendix a, Appendix a, “state and status information, Appendix
![background image](/manuals/361658/311/background.png)
Fabric OS Encryption Administrator’s Guide (SKM/ESKM)
291
53-1002923-01
Appendix
A
State and Status Information
In this appendix
•
Encryption engine security processor (SP) states . . . . . . . . . . . . . . . . . . . . 291
•
•
Encryption engine security processor (SP) states
lists the encryption engine security processor (SP) states.
TABLE 19
Encryption engine security processor (SP) states
Encryption engine security processor (SP) state Description
Not available
SLOT_XXX_SCN has not been received (debug message).
Not Brocade Encryption Switch or DCX
Debug message.
Not Ready
BLADE_RDY_SCN has not been received (debug message).
Fail to connect to blade
Encryption engine is not connected to the blade processor.
Starting
BLADE_RDY_SCN received and initializing.
SPC Connecting to SP
Establishing connection to CP.
SPC Connected to SP
Connection to CP established.
SP Initialized
SP initialization completed.
Waiting for initnode
SP is awaiting initialization. Run initnode.
Disabled SP
is
disabled.
Encryption engine Faulty
Encryption engine is faulty (BP fault or SP fault). Issue reboot.
Waiting for initEE
SP is awaiting initialization. Run initEE.
Waiting for regEE
SP has its own certificates but is awaiting FIPS certificates. Run
regEE.
Waiting for enableEE
Awaiting the explicit enabling of encryption engine. Run enableEE.
Operational; Not Online
Encryption engine is operational but offline.
Operational; Need Valid KEK
No current master key or primary or secondary link key. Check the
KEK status for more details.
Operational; Need Encryption Group
Encryption engine is operational, but EG is not configured or EG
information is not available. Check EG status.
Online
Encryption engine is online.
Zeroized
Encryption engine is zeroized
INVALID
Encryption engine is invalid