Measuring encryption performance
6
b. The user port on which a particular virtual entity is hosted can be identified from the Port
Index of the corresponding name server entry. For example, the port on which virtual
target 20:00:00:05:1e:55:4d:61 has been hosted can be identified by the following
command.
FabricAdmin:switch> nsshow | grep -A 6 20:00:00:05:1e:55:4d:61
N 012001; 3;20:00:00:05:1e:55:4d:61;20:01:00:05:1e:55:4d:61; na
FC4s: FCP
PortSymb: [21] "Crypto Virtual Target"
NodeSymb: [54] "Cntr Name: tape1 Tgt Port wwn: 50:01:10:A0:00:8D:F6:8A"
Fabric Port Name: 20:20:00:05:1e:55:4d:5e
Permanent Port Name: 20:00:00:05:1e:55:4d:61
Port Index: 32
Share Area: No
Device Shared in Other AD: No
Redirect: Yes virtual
Partial: No
LSAN: No
c. Similarly, the port on which virtual initiator 20:02:00:05:1e:55:4d:61 is hosted can be
identified by following command.
FabricAdmin:switch> nsshow | grep -A 6 20:02:00:05:1e:55:4d:61
N 012401; 3;20:02:00:05:1e:55:4d:61;20:03:00:05:1e:55:4d:61; na
FC4s: FCP
PortSymb: [24] "Crypto Virtual Initiator"
NodeSymb: [37] "Ini Port wwn: 10:00:00:05:1E:C3:2D:9B"
Fabric Port Name: 20:24:00:05:1e:55:4d:5e
Permanent Port Name: 20:02:00:05:1e:55:4d:61
Port Index: 36
Share Area: No
Device Shared in Other AD: No
Redirect: Yes virtual
Partial: No
LSAN: No
2. Determine the “perfshow” output for the Brocade Encryption Switch or blade.
a. Execute the cryptocfg
–
perfshow [slot] command to determine the I/O throughput.
FabricAdmin:switch> cryptocfg --perfshow
32
33
34
35
36
37
38
39
40
41
42
43
=====
=====
=====
=====
====
====
====
====
====
====
====
====
5.4m
5.1m
0
0
0
0
5.4m
47.5m
0
0
0
0
44
45
46
47
48
49
50
51
52
53
54
55
Total
=====
=====
=====
=====
====
====
====
====
====
====
====
====
0
0
0
0
0
0
0
0
0
0
0
0
75.6m