beautypg.com

Space reclamation – Brocade Fabric OS Encryption Administrator’s Guide Supporting HP Secure Key Manager (SKM) and HP Enterprise Secure Key Manager (ESKM) Environments (Supporting Fabric OS v7.2.0) User Manual

Page 216

background image

196

Fabric OS Encryption Administrator’s Guide (SKM/ESKM)

53-1002923-01

Thin provisioned LUNs

3

Encryption format: native

Encrypt existing data: disabled

Rekey: disabled

Internal EE LUN state: Encryption enabled

Encryption algorithm: AES256-XTS

Key ID state: Read write

New LUN: No

TP LUN:

Yes

Key ID: 4b:d9:4d:12:93:67:0e:0d:d1:e0:ca:aa:ba:34:29:db

Key creation time: Thu Sep 15 18:01:01 2011

FabricAdmin:switch> cryptocfg –discoverLUN -container

Host: 21:00:00:e0:8b:90:7c:c0

LUN number: 0xd

LUN serial number: 50002AC000BC0A50

TP LUN:

Yes

LUN connectivity state: Connected

Key ID state: Key ID not Applicable

FabricAdmin:switch> cryptocfg --show -rekey –all

LUN number: 0x0

LUN serial number: 50002AC002E70A50

TP LUN:Yes

Rekey session number: 0

Percentage complete: 98

Rekey state: Read Phase

Rekey role: Primary/Active

Block size: 512

Number of blocks: 4194304

Current LBA: 4141617

FabricAdmin:switch> cryptocfg –-show –LUN tpdisk 0 10:00:00:00:c9:29:0f:01 –

stat

LUN number: 0x0

LUN type: disk

LUN serial number: 50002AC002E70A50

TP LUN:

Yes

Encryption mode: encrypt

Encryption format: native

Encrypt existing data: disabled

Rekey: disabled

Internal EE LUN state: Encryption enabled

Encryption algorithm: AES256-XTS

Key ID state: Read write

New LUN: No

Key ID: d3:a6:de:b9:67:26:04:fa:b9:83:e1:c7:cf:ae:f1:9c

Key creation time: Fri Feb 17 03:41:54 2012

Space reclamation

When a block that was provisioned is no longer needed, it can be reclaimed. The Brocade
Encryption Switch supports following methods to reclaim the provisioned blocks:

Sending the UNMAP SCSI command

Note the following limitations:

The Host will get garbled data while trying to read an unmapped region.