Watlow EZ-ZONE
®
RMS Module
•
61
•
Chapter 4 Setup Page
RM Scanner Module
•
Setup Page
Display
Parameter Name
Description
Range
Default
Modbus
Relative
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Parameter
ID
Data
Type
&
Read/
Write
[`oP;9]
[ op.9]
Linearization (1 to 24)
Output Point 9
Set the value that will be
mapped to input 9.
-1,999.000 to 9,999.000 °F or
units
-1,128.333 to 5537.223 °C
8.0
11390
[offset 70]
0x86 (134)
1 to 0x18
(24)
0x1A (26)
105
34026
float
RWES
[iP;10]
[ip.10]
Linearization (1 to 24)
Input Point 10
Set the value that will be
mapped to output 10.
-1,999.000 to 9,999.000 °F or
units
-1,128.333 to 5537.223 °C
9.0
11372
[offset 70]
0x86 (134)
1 to 0x18
(24)
0x11 (17)
106
34017
float
RWES
[oP;10]
[op.10]
Linearization (1 to 24)
Output Point 10
Set the value that will be
mapped to input 10.
-1,999.000 to 9,999.000 °F or
units
-1,128.333 to 5537.223 °C
9.0
11392
[offset 70]
0x86 (134)
1 to 0x18
(24)
0x1B (27)
107
34027
float
RWES
[`CPE]
[`Set]
Compare Menu
[``Fn]
[ Fn]
Compare (1 to 24)
Function
Set operator that will be
used to compare Source A
to Source B.
[`oFF]
Off (62)
[``g;t]
Greater Than (1435)
[``L;t]
Less Than (1436)
[```E]
Equal To (1437)
[``nE]
Not Equal To (1438)
[`goE]
Greater or Equal
(1439)
[`LoE]
Less or Equal (1440)
Off
8236
[offset 40]
0x80 (128)
1 to 0x18
(24)
9
137
28009
uint
RWES
[`toL]
[ toL]
Compare (1 to 24)
Tolerance
If the difference between
Source A and Source B is
less than this value the two
will appear to be equal.
0 to 9,999.000
0.1
8240
[offset 40]
0x80 (128)
1 to 0x18
(24)
0xB (11)
138
28011
float
RWES
[SFn;A]
[SFn.A]
Compare (1 to 24)
Source Function A
Set the type of function
that will be used for this
source.
[nonE]
None (61)
[``Ai]
Analog Input (142)
[CUrr]
Current (22)
[`C;Pr]
Cool Power, Control
Loop (161)
[`h;Pr]
Heat Power, Control
Loop (160)
[PWr]
Power, Control Loop
(73)
[`Lnr]
Linearization (238)
[MAt]
Math (240)
[``Pu]
Process Value (241)
[`SP;C]
Set Point Closed,
Control Loop (242)
[`SP;o]
Set Point Open, Con-
trol Loop (243)
[`uAr]
Variable (245)
None
8220
[offset 40]
0x80 (128)
1 to 0x18
(24)
1
- - - -
28001
uint
RWES
[`Si;A]
[ Si.A]
Compare (1 to 24)
Source Instance A
Set the instance of the
function selected above.
1 to 250
1
8224
[offset 40]
0x80 (128)
1 to 0x18
(24)
3
- - - -
28003
uint
RWES
Note: Some values will be rounded off to fit in the four-character display .
Full values can be read with other interfaces .
If there is only one instance of a menu, no submenus will appear .
R: Read
W: Write
E:
EEPROM
S:
User
Set