Linearization menu – Watlow EZ-ZONE RM-Scanner-Modul User Manual

Page 41

background image

Watlow EZ-ZONE

®

RMS Module

38

Chapter 3 Operations Page

RM Scanner Module

Operations Page

Display

Parameter Name

Description

Range

Default

Modbus

Relative

Address

CIP

Class

Instance

Attribute

hex (dec)

Profibus

Index

Parameter

ID

Data

Type

& Read/

Write

No Dis-

play

Alarm (1 to 16)

Silenced

Read this register to de-

termine if the alarm is

silenced

No (59)
Yes (106)

None

2520
[offset 60]

0x6D

(109)

1 to 0x10

(16)

0x0B (11)

- - - -

9011

uint

R

No Dis-

play

Alarm (1 to 16)

Clearable

Read to determine if an

alarm can be cleared

No (59)
Yes (106)

None

2522
[offset 60]

0x6D

(109)

1 to 0x10

(16)

0xC (12)

- - - -

9012

uint

R

No Dis-

play

Alarm (1 to 16)

Clear Request

Write to this register to

clear an alarm

Clear (0)
No Change (255)

None

2524
[offset 60]

0x6D

(109)

1 to 0x10

(16)

0xD (13)

32

9013

uint

RW

No Dis-

play

Alarm (1 to 16)

Silence Request

Write to this register to

silence an alarm

Clear (0)
No Change (255)

None

2526
[offset 60]

0x6D

(109)

1 to 0x10

(16)

0x0E (14)

33

9014

uint

RW

No Dis-

play

Alarm (1 to 16)

Alarm Working Process

Value

Read process value used

by alarms

-1,999.000 to 9,999.000°F

or units

-1,128.000 to 5,537.000°C

None

2536
[offset 60]

0x6D

(109)

1 to 0x10

(16)

0x13 (19)

- - - -

9019

float

R

No Dis-

play

Alarm (1 to 16)

Alarm Working Set

Point

Read set point used by

alarms

-1,999.000 to 9,999.000°F

or units

-1,128.000 to 5,537.000°C

None

2538
[offset 60]

0x6D

(109)

1 to 0x10

(16)

0x14 (20)

- - - -

9020

float

R

No Dis-

play

Alarm (1 to 16)

Output Value

Read state of alarm out-

put

On (63)

Off (62)

None

2546
[offset 60]

0x6D

(109)

1 to 0x10

(16)

0x18 (24)

- - - -

9024

uint

R

[`Lnr]
[oPEr]
Linearization Menu

[`Su;A]
[ Su.A]

Linearization (1 to 24)

Source Value A

View the value of Source

A.

-1,999.000 to 9,999.000°F

or units

-1,128.000 to 5,537.000°C

11346
[offset 70]

0x86

(134)

1 to 0x18

(24)

4

- - - -

34004

float
R

[oFSt]
[oFSt]

Linearization (1 to 24)

Offset

Set an offset to be applied

to this function's output.

-1,999.000 to 9,999.000°F

or units

-1,128.000 to 5,537.000°C

0

11350
[offset 70]

0x86

(134)

1 to 0x18

(24)

6

- - - -

34006

float
RWES

[``o;u]
[ o.v]

Linearization (1 to 24)

Output Value

View the value of this

function's output.

-1,999.000 to 9,999.000°F

or units

-1,128.000 to 5,537.000°C

11352
[offset 70]

0x86

(134)

1 to 0x18

(24)

7

- - - -

34007

float
R

Note: Some values will be rounded off to fit in the four-character display . Full values
can be read with other interfaces .

If there is only one instance of a menu, no submenus will appear .

R: Read

W: Write

E: EEPROM

S: User Set