5 cf card installation, Nstallation – IEI Integration WAFER-945GSELVDS2 User Manual
Page 57

WAFER-945GSELVDS2
Page 45
Step 3:
Insert the SO-DIMM. Push the SO-DIMM chip into the socket at an angle. (See
Step 4:
Open the SO-DIMM socket arms. Gently pull the arms of the SO-DIMM socket
out and push the rear of the SO-DIMM down. (See Figure 4-1)
Step 5:
Secure the SO-DIMM. Release the arms on the SO-DIMM socket. They clip into
place and secure the SO-DIMM in the socket.
Step 0:
4.5 CF Card Installation
NOTE:
The WAFER-945GSELVDS2 can support both CF Type I cards and CF
Type II cards. For the complete specifications of the supported CF
cards please refer to Chapter 2.
To install the a CF card (Type 1 or Type 2) onto the WAFER-945GSELVDS2, please
follow the steps below:
Step 1:
Locate the CF card socket. Place the WAFER-945GSELVDS2 on an anti-static
pad with the solder side facing up. Locate the CF card.
Step 2:
Align the CF card. Make sure the CF card is properly aligned with the CF
socket.
Step 3:
Insert the CF card. Gently insert the CF card into the socket making sure the
socket pins are properly inserted into the socket. See Figure 4-2.
Step 0: