13 serial port console redirection – IEI Integration IMB-Q770 User Manual
Page 116

IMB-Q770 Mic ro -ATX Mo th e rb o a rd
P a g e 100
Auto Duty-Cycle
Mode
D
EFAULT
The fan adjusts its speed using Auto by
Duty-Cycle settings
PCH Tem p eratu re n
Use the + or – key to change the fan PCH Temperature n value. Enter a decimal number
between 1 and 100.
SYS_FAN1 Sm a rt Fan Co n tro l [Au to Du ty-Cycle Mo d e]
Use the SYS_FAN1 Smart Fan Control option to configure the System Smart Fan.
Manual Duty
Mode
The fan spins at the speed set in Manual by Duty
Cycle settings
Auto Duty-Cycle
Mode
D
EFAULT
The fan adjusts its speed using Auto by
Duty-Cycle settings
SYS Tem p eratu re n
Use the + or – key to change the fan SYS Temperature n value. Enter a decimal number
between 1 and 100.
5.3.13 S e ria l P o rt Co n s o le Re d ire c tio n
The Serial Port Console Redirection menu (BIOS Menu 18) allows the console
redirection options to be configured. Console redirection allows users to maintain a
system remotely by re-directing keyboard input and text output through the serial port.