background image

68

5. RCS-C and E-Con

4.4 Input/Output

(I/O)

The I/O specifications of RCS-C and E-Con controllers are as follows:
(1) RCS-C: 8 dedicated input points, 10 dedicated output points
(2) E-Con: 10 dedicated input points, 12 dedicated output points
The details are explained below.

For details on each signal, refer to the “Operation Manual for RCS Series ROBO
Cylinder Controller, RCS-C Type” or “Operation Manual for E-Con Controller.”)

(1) RCS-C signal assignments

8-bit input

10-bit output

Input No.

Signal name

Output No.

Signal name

0

Command position 1

0

Completed position 1

1

Command position 2

1

Completed position 2

2

Command position 4

2

Completed position 4

3

Command position 8

3

Completed position 8

4 Start 4

Position

complete

5 Reset 5

Home

return complete

6 Servo

on 6 Zone

7 *Pause 7 *Alarm

8

Not used

8

*Emergency stop

9 Not

used 9 Moving

10

Not used

10

*Battery alarm (Note 1)

11

Not used

11

Not used (Note 2)

12 Not

used 12 Not

used

13 Not

used 13 Not

used

14 Not

used 14 Not

used

15 Not

used 15 Not

used

The signals denoted by * are always ON.
(Note 1) This signal is available only on controllers that operate on a mains voltage of 100 or 200 V. The

ON/OFF state of the signal is indeterminable on 24-VDC controllers.

(Note 2) The ON/OFF state of signals denoted by “Not used” is indeterminable.