IAI America E-Con User Manual
Page 26
18
2. X-SEL-J/K/P/Q/JX/KX/PX/QX
2.4.2 Factory-set
Parameters
(1) Factory-set parameters for J/K types
No.
Parameter name
Input range
Setting
Remarks
1
I/O port assignment type
0 ~ 20
0
0: Fixed assignment
1: Automatic assignment (Priority: Assigned
from slot 1)
* Ports are assigned consecutively only for
slots where a board is physically installed,
starting from slot 1, for safety reasons.
2
Input port start number for standard I/O
based on fixed assignment (I/O1)
-1 ~ 599
000
0 + (multiple of 8) (Invalid, if a value is entered
with a negative sign.)
3
Output port start number for standard
I/O based on fixed assignment (I/O1)
-1 ~ 599
300
300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)
4
Input port start number for expansion
I/O1 based on fixed assignment (I/O2)
-1 ~ 599
-1
0 + (multiple of 8) (Invalid, if a value is entered
with a negative sign.)
(Slot immediately next to the standard I/O slot)
5
Output port start number for expansion
I/O1 based on fixed assignment (I/O2)
-1 ~ 599
-1
300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)
6
Input port start number for expansion
I/O2 based on fixed assignment (I/O3)
-1 ~ 599
-1
0 + (multiple of 8) (Invalid, if a value is entered
with a negative sign.)
7
Output port start number for expansion
I/O2 based on fixed assignment (I/O3)
-1 ~ 599
-1
300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)
8
Input port start number for expansion
I/O3 based on fixed assignment (I/O4)
-1 ~ 599
-1
0 + (multiple of 8) (Invalid, if a value is entered
with a negative sign.)
9
Output port start number for expansion
I/O3 based on fixed assignment (I/O4)
-1 ~ 599
-1
300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)
10 Error monitor for standard I/O (I/O1)
0 ~ 5
2
11 Error monitor for expansion I/O1 (I/O2)
0 ~ 5
0
12 Error monitor for standard I/O2 (I/O3)
0 ~ 5
0
13 Error monitor for expansion I/O3 (I/O4)
0 ~ 5
0
0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power
supply errors)
(Main application version 0.55 or
later)
3: Monitor (Monitor 24-V I/O power supply
errors only)
(Main application version 0.55 or
later)
14 Number of ports used for remote input
via network I/F card
0 ~ 256
64
Multiple of 8
15 Number of ports used for remote
output via network I/F card
0 ~ 256
64
Multiple of 8
I/O1 through I/O4 indicate slot numbers.