5. RCS-C and E-Con
4.3.2 DIP
Switch
Settings
The DIP switches are used to set the following items:
(1) Node
address
(2) Baud
rate
(Note) Turn off the X-SEL power before setting the DIP switches.
(1) Setting the node address (MAC ID)
Set the node address (MAC ID) using a hexadecimal value according to the table below.
1: ON 0: OFF
DIP
switches
Node address
(MAC ID)
NA5 NA4 NA3 NA2 NA1 NA0
0 0 0 0 0 0 0
1 0 0 0 0 0 1
2 0 0 0 0 1 0
3 0 0 0 0 1 1
}
}
}
}
}
}
}
60 1 1 1 1 0 0
61 1 1 1 1 0 1
62 1 1 1 1 1 0
63 1 1 1 1 1 1
(Note) The node address corresponds to the remote I/O address in the PLC. (For details, refer to the
operation manual for the PLC.)
(2) Setting the baud rate
Set the baud rate according to the table below.
1: ON 0: OFF
DIP
switches
Baud rate
DR1
DR0
125 kbps
0
0
250 kbps
0
1
500 kbps
1
0
Setting prohibited
1
1