(2) Factory-set parameters for TT type

No.

Parameter name

Input range

Setting

Remarks

1

I/O port assignment type

0

Reference

only

0: Fixed assignment

2

Input port start number for standard
I/O1 based on fixed assignment

000

Reference

only

0 + (multiple of 8) (Invalid, if a value is entered
with a negative sign.)

3

Output port start number for standard
I/O1 based on fixed assignment

300

Reference

only

300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

4

Input port start number for standard
I/O2 based on fixed assignment

32

Reference

only

0 + (multiple of 8) (Invalid, if a value is entered
with a negative sign.)

5

Output port start number for standard
I/O2 based on fixed assignment

316

Reference

only

300 + (multiple of 8) (Invalid, if a value is
entered with a negative sign.)

6

Input port start number for expansion
I/O1 based on fixed assignment
(Network I/F module)

48

-1 ~ 599 0 + (multiple of 8) (Invalid, if a value is entered

with a negative sign.)

7

Output port start number for expansion
I/O1 based on fixed assignment
(Network I/F module)

348

-1 ~ 599 300 + (multiple of 8) (Invalid, if a value is

entered with a negative sign.)

8

Reserved by the system

-1

-1 ~ 599

9

Reserved by the system

-1

-1 ~ 599

10 Error monitor for standard I/O1

0

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power

supply errors)

3: Monitor (Monitor 24-V I/O power supply

errors only)

* Some exceptions apply.

11 Error monitor for standard I/O2

0

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor 24-V I/O power

supply errors)

3: Monitor (Monitor 24-V I/O power supply

errors only)

* Some exceptions apply.

12 Error monitor for expansion I/O1

(Network I/F module)

1

0 ~ 5

0: Do not monitor
1: Monitor
* Some exceptions apply.

13 Reserved by the system

1

0 ~ 5

14 Number of ports used for remote input

via network I/F card

64

0 ~ 240

Multiple of 16

15 Number of ports used for remote

output via network I/F card

64

0 ~ 240

Multiple of 16

On TT robots, the numbers of available DeviceNet ports can be changed using applicable parameters.
The DeviceNet I/O port start numbers are fixed.
DeviceNet input port start No. 48
DeviceNet output port start No. 348

The I/O port numbers for standard I/Os (connected via the rear panel I/O connector) are fixed.
Standard input port Nos. 16 to 31
Standard output port Nos. 316 to 331