IAI America E-Con User Manual
Page 48
40
3. XSEL-R/S/RX/SX/RXD/SXD
[3] DeviceNet Board Use Setting
Set “1” (Monitoring: use DeviceNet board) to I/O Parameter No.235.
No.
Parameter name
Default
(Reference)
Input Range
Unit
Remarks
235
Network I/F Module 2
Error Monitoring
1
0 to 5
─
0:No Monitoring (Not to monitor
condition of link to PLC (master))
1:Monitoring
[4] Node address setting
Set the node address to I/O Parameter No. 237
No.
Parameter name
Default
(Reference)
Input Range
Unit
Remarks
237
Network I/F Module 2
Node Address
0
0 to 63
─
DeviceNet node address range:
0 to 63
Note If a number out of the settable range is selected, “D75: Fieldbus Parameter Error” will occur.
[5] Baud Rate Setting
Set the communication speed in I/O Parameter No. 238. Match the setting to the communication speed of
the master unit.
No.
Parameter name
Default
(Reference)
Input Range
Unit
Remarks
238
Network I/F Module 2
Baud Rate
0
0 to 2
─
0: 125Kbps
1: 250Kbps
2: 500Kbps
Note If a number out of the settable range is selected, “D75: Fieldbus Parameter Error” will occur.
[6] Number of I/O Port Setting
Set the number of ports to be used for I/O Parameters No. 231 to 232.
Note Set a number that is a multiple of 8.
No.
Parameter name
Default
(Reference)
Input Range
Unit
Remarks
231
No. of Network I/F
Module 2 Remote
Input Ports
0
0 to 256
─
8 port unit
232
No. of Network I/F
Module 2 Remote
Output Ports
0
0 to 256
─
8 port unit